Patient dose in angiographic interventional procedures: A multicentre study in Italy

被引:10
作者
Isoardi, Paola [1 ]
D'Ercole, Loredana [2 ]
Cavallari, Monica [2 ,3 ]
Gianusso, Laura [1 ]
Pini, Silvia [4 ]
Giordano, Carlo [5 ]
Angelini, Lidia [6 ]
Colombo, Paola Enrica [7 ]
Delle Canne, Stefania [8 ]
Del Vecchio, Antonella [9 ]
Di Liberto, Riccardo [10 ]
Farnedi, Simona [11 ]
Ghetti, Caterina [12 ]
Lorenzini, Elena [13 ]
Origgi, Daniela [14 ]
Paruccini, Nicoletta [15 ]
Pasquino, Massimo [16 ]
Cutaia, Claudia [16 ]
Quattrocchi, Mariagrazia [17 ]
Riccardi, Lucia [18 ]
Soavi, Raffaella [19 ]
Strocchi, Sabina [20 ,21 ]
Trianni, Annalisa [22 ]
Venturi, Giovanna [23 ]
机构
[1] AOU Citta Salute & Sci, Turin, Italy
[2] Fdn IRCCS Policlin San Matteo, Pavia, Italy
[3] Univ Milan, Milan, Italy
[4] USL Toscana Ctr, Florence, Italy
[5] AUSL, Piacenza, Italy
[6] Azienda USL Romagna AT Rimini, Rimini, Italy
[7] ASST Grande Osped Metropolitano Niguarda, Milan, Italy
[8] Osped San Giovanni Calibita, Fatebenefratelli Isola Tiberina, Rome, Italy
[9] IRCCS Osped San Raffaele, Milan, Italy
[10] Fdn IRCCS Policlin San Matteo Pavia, ASST Lodi, Pavia, Italy
[11] Azienda USL Romagna, Ambito Ravenna, Ravenna, Italy
[12] Univ Parma, Azienda Osped, Parma, Italy
[13] Azienda Toscana Nord Ovest, Massa, Italy
[14] Ist Europeo Oncol IRCCS, IEO, Milan, Italy
[15] ASST Monza, San Gerardo, Italy
[16] AO Ordine Mauriziano, Turin, Italy
[17] Azienda Toscana Nord Ovest, Lucca, Italy
[18] IRCCS, Veneto Inst Oncol IOV, Padua, Italy
[19] Osped Maggiore AUSL Bologna, Bologna, Italy
[20] ASST Sette Laghi Osped Circolo, Varese, Italy
[21] Polo Univ Varese, Fdn Macchi, Varese, Italy
[22] Azienda Sanitaria Univ Integrata Udine, Udine, Italy
[23] Azienda USL Romagna AT Forli, Forli, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 64卷
关键词
DIAGNOSTIC REFERENCE LEVELS; REDUCING RADIATION-EXPOSURE; NOISE-REDUCTION TECHNOLOGY; NEUROINTERVENTIONAL PROCEDURES; IMAGE INTENSIFIER; CATHETER ABLATION; IMPLANTATION; FLUOROSCOPY; RADIOLOGY; SYSTEMS;
D O I
10.1016/j.ejmp.2019.06.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Council Directive 2013/59/EURATOM considers interventional radiology to be a special practice involving high doses of radiation and requiring strict monitoring to ensure the best quality assurance programs. This work reports the early experience of managing dose data from patients undergoing angiography in a multicentre study. Materials and methods: The study was based on a survey of about 15,200 sample procedures performed in 21 Italian hospitals centres involved on a voluntary basis. The survey concerned the collection of data related to different interventional radiology procedures: interventional cardiology, radiology, neuroradiology, vascular surgery, urology, endoscopy and pain therapy from a C-Arm and fixed units. The analysis included 11 types of procedures and for each procedure, air-kerma, kermaarea product and fluoroscopy time were collected. Results: The duration and dose values of fluoroscopic exposure for each procedure is strongly dependent on individual clinical circumstances including the complexity of the procedure; the observed distribution of patient doses was very wide, even for a specified protocol. The median values of the parameters were compared with the diagnostic reference levels (DRL) proposed for some procedures in Italy (ISTISAN) or internationally. This work proposes local DRL values for three procedures. Conclusion: This first data collection serves to take stock of the situation on patient's dosimetry in several sectors and is the starting point for obtaining and updating DRL recalling that these levels are dependent on experience and technology available.
引用
收藏
页码:273 / 292
页数:20
相关论文
共 50 条
  • [31] Patient radiation doses in paediatric interventional cardiology procedures: a review
    Harbron, R. W.
    Dreuil, S.
    Bernier, M-O
    Pearce, M. S.
    Thierry-Chef, I.
    Chapple, C-L
    Baysson, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : R131 - R144
  • [32] Patient exposure data and operator dose in coronary interventional procedures: Impact of body-mass index and procedure complexity
    Zanca, Federica
    Collard, Celine
    Alexandre, Nicolas
    Deprez, Frederic
    Salembier, Jean Paul
    Henry, Michel
    Rombaut, Emmanuel
    Massart, Pierre-Emmanuel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 38 - 43
  • [33] Reference levels and patient doses in interventional cardiology procedures in Greece
    Simantirakis, George
    Koukorava, Christina
    Kalathaki, Maria
    Pafilis, Christos
    Kaisas, Ioannis
    Economides, Sotirios
    Hourdakis, Costas J.
    Kamenopoulou, Vassiliki
    Georgiou, Evaggelos
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2324 - 2332
  • [34] AN INVESTIGATION OF PATIENT DOSES DURING CORONARY INTERVENTIONAL PROCEDURES IN CHINA
    Cui, Yanhai
    Zhang, Hongdan
    Zheng, Junhui
    Yang, Xiangtai
    Liang, Changhong
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (03) : 296 - 302
  • [35] Radiation Dose in CT-guided Interventional Procedures: Establishing a Benchmark
    Leng, Shuai
    RADIOLOGY, 2018, 289 (01) : 158 - 159
  • [36] Patients dose and risk assessment in fluoroscopically guided interventional procedures in Ghana
    Issahaku, Shiraz
    Hasford, Francis
    Azantillow, Norbert
    Sackey, Theophilus Akumea
    Nunoo, George
    Dzefi-Tettey, Klenam
    Mensah, Yaw Boateng
    Sarkodie, Benjamin
    Amponsah, Becky Appiah
    Tagoe, Samuel
    Esposito, Marco
    Padovani, Renato
    HEALTH AND TECHNOLOGY, 2025, 15 (01) : 119 - 130
  • [37] Medical staff dose estimation during pediatric cardiac interventional procedures
    Roberto, Maryanna Regina
    Leite, Luiz M. A.
    Cruz, Aricia R. P.
    Khoury, Helen
    de Barros, Vinicius S. M.
    Neves, Juliana R.
    Cartaxo, Jessica M.
    Ubeda, Carlos
    Asfora, Viviane K.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [38] Analysis of factors that affect radiation dose level during interventional cardiology procedures using logistic regression
    Harki, Edrees M.
    Rashid, Z. S.
    REVISTA MEXICANA DE FISICA, 2023, 69 (03)
  • [39] Dose reduction for fluoroscopically guided injections: phantom simulation and patient procedures
    Chang, C. Y.
    Simeone, F. J.
    DeLorenzo, M. C.
    Palmer, W. E.
    Bredella, M. A.
    Huang, A. J.
    SKELETAL RADIOLOGY, 2018, 47 (02) : 223 - 231
  • [40] ASSESSMENT OF PATIENT'S PEAK SKIN DOSE USING GAFCHROMIC FILMS DURING INTERVENTIONAL CARDIOLOGY PROCEDURES: ROUTINE EXPERIENCE FEEDBACK
    Greffier, J.
    Moliner, G.
    Pereira, F.
    Cornillet, L.
    Ledermann, B.
    Schmutz, L.
    Lomma, M.
    Cayla, G.
    Beregi, J. P.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 395 - 405