Noninvasive measurement of dissolved oxygen in shake flasks

被引:81
作者
Tolosa, L [1 ]
Kostov, Y [1 ]
Harms, P [1 ]
Rao, G [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Baltimore, MD 21250 USA
关键词
oxygen sensor; non-invasive sensor; shake flask fermentation;
D O I
10.1002/bit.10409
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Shake flasks are ubiquitous in cell culture and fermentation. However, conventional devices for measuring oxygen concentrations are impractical in these systems. Thus, there is no definitive information on the oxygen supply of growing cells. Here we report the noninvasive, nonintrusive monitoring of dissolved oxygen (DO) in shake flasks using a low-cost optical sensor. The oxygen-sensitive element is a thin, luminescent patch affixed to the inside bottom of the flask. The sensitivity and accuracy of this device is maximal up to 60% DO, within the range that is critical to cell culture applications. By measuring actual oxygen levels every 1 or 5 min throughout the course of yeast and E. coli fermentations, we found that a modest increase in shaker speed and a decrease in culture volume slowed the onset of oxygen limitation and reduced its duration. This is the first time that in situ oxygen limitation is reported in shake flasks. The same data is unattainable with a Clark type electrode because the presence of the intrusive probe itself changes the actual conditions. Available fiber optic oxygen sensors require cumbersome external connections and recalibration when autoclaved. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:594 / 597
页数:4
相关论文
共 14 条
[1]   DEVELOPMENT OF SCALE-DOWN TECHNIQUES FOR INVESTIGATION OF RECOMBINANT ESCHERICHIA-COLI FERMENTATIONS - ACID METABOLITES IN SHAKE FLASKS AND STIRRED BIOREACTORS [J].
DAHLGREN, ME ;
POWELL, AL ;
GREASHAM, RL ;
GEORGE, HA .
BIOTECHNOLOGY PROGRESS, 1993, 9 (06) :580-586
[2]   IMPROVED SHAKEN FLASK PERFORMANCE [J].
GADEN, EL .
BIOTECHNOLOGY AND BIOENGINEERING, 1962, 4 (01) :99-&
[3]   Ratiometric oxygen sensing: detection of dual-emission ratio through a single emission filter [J].
Kostov, Y ;
Harms, P ;
Pilato, RS ;
Rao, G .
ANALYST, 2000, 125 (06) :1175-1178
[4]   Unique oxygen analyzer combining a dual emission probe and a low-cost solid-state ratiometric fluorometer [J].
Kostov, Y ;
Van Houten, KA ;
Harms, P ;
Pilato, RS ;
Rao, G .
APPLIED SPECTROSCOPY, 2000, 54 (06) :864-868
[5]  
Lakowicz J.R., 2004, PRINCIPLES FLUORESCE, VSecond
[6]  
LOCHER G, 1992, J BIOTECHNOL, V25, P25
[7]   EFFECT OF SHAKING SPEED AND TYPE OF CLOSURE ON SHAKE FLASK CULTURES [J].
MCDANIEL, LE ;
BAILEY, EG .
APPLIED MICROBIOLOGY, 1969, 17 (02) :286-&
[8]   A DISCUSSION OF RECENT DEVELOPMENTS IN FERMENTATION MONITORING AND CONTROL FROM A PRACTICAL PERSPECTIVE [J].
ROYCE, PN .
CRITICAL REVIEWS IN BIOTECHNOLOGY, 1993, 13 (02) :117-149
[9]  
Scheper Thomas-Helmut, 1994, Current Opinion in Biotechnology, V5, P187, DOI 10.1016/S0958-1669(05)80034-5
[10]   COTTON CLOSURE AS AERATION BARRIER IN SHAKEN FLASK FERMENTATIONS [J].
SCHULTZ, JS .
APPLIED MICROBIOLOGY, 1964, 12 (04) :305-&