Diagnostic of infection after total knee replacement

被引:20
作者
Kordelle, J
Klett, R
Stahl, U
Hossain, H
Schleicher, I
Haas, H
机构
[1] Univ Giessen Klinikum, Klin & Poliklin Orthopad & Orthopad Chirurg, D-35385 Giessen, Germany
[2] Univ Giessen Klinikum, Klin Nukl Med, D-6300 Giessen, Germany
[3] Univ Giessen Klinikum, Inst Pathol, D-6300 Giessen, Germany
[4] Univ Giessen Klinikum, Inst Mikrobiol, D-6300 Giessen, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2004年 / 142卷 / 03期
关键词
joint aspiration; polymerase chain reaction (PCR); laboratory parameters; scintigraphy; total knee replacement;
D O I
10.1055/s-2004-818772
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: In this study, the accuracy of antigranulocyte scintigraphy as a diagnostic means prior to revision in infected total knee replacement was compared to that of preoperative joint aspiration and laboratory parameters. The most efficient combination of all diagnostic methods was calculated and thus a diagnostic algorithm recommended. The value of PCR was compared to commonly used techniques of microbiological culturing. Methods: Preoperative diagnostic means for infection of 50 total knee replacements in 45 patients requiring revision surgery, were retrospectively analyzed. Inclusion criteria were the intraoperative microbiological and histological verification of infection. Sensitivity, specificity, negative and positive prediction value of C-reactive protein (CRP) and leukocytes, antigranulocyte scintigraphy with Tc-99m-labeled antibodies, and preoperative joint aspiration were calculated. Furthermore, the accuracy of the different techniques of culturing was compared to that of the polymerase chain reaction (PCR) based on the intraoperative histological findings. Two blinded examiners evaluated specimens taken intraoperatively according to the criteria of Mirra. Results: We observed a sensitivity of 1.0, a specificity of 0.82, a positive prediction value of 0.83 and a negative prediction value of 1.0 for the antigranulocyte scintigraphy. The sensitivity of preoperative joint aspiration was 0.5, the specificity 1.0, and the positive and negative prediction values were 1.0 and 0.5. Correlated to the intraoperative histological findings the accuracy of PCR and culturing was comparable. The highest accuracy was obtained for blood culture samples. Conclusion: Compared to preoperative joint aspiration the antigranulocyte scintigraphy proved to be more sensitive in the diagnosis an infected knee replacement while having a high specificity. An advantage of PCR compared to the common microbiological culturing techniques was not observed.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [31] Effect of patient characteristics on reported outcomes after total knee replacement
    Escobar, A.
    Quintana, J. M.
    Bilbao, A.
    Azkarate, J.
    Guenaga, J. I.
    Arenaza, J. C.
    Gutierrez, L. F.
    RHEUMATOLOGY, 2007, 46 (01) : 112 - 119
  • [32] Impact of Sarcopenia and Obesity on Gait Speed After Total Knee Replacement
    Liao, Chun-De
    Chen, Hung-Chou
    Liou, Tsan-Hon
    Lin, Che-Li
    Huang, Shih-Wei
    JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2022, 23 (04) : 631 - 637
  • [33] Patellofemoral kinematics during deep knee flexion after total knee replacement: a computational simulation
    Huang, Chang-Hung
    Hsu, Lin-I
    Lin, Kun-Jhih
    Chang, Ting-Kuo
    Cheng, Cheng-Kung
    Lu, Yung-Chang
    Chen, Chen-Sheng
    Huang, Chun-Hsiung
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3047 - 3053
  • [34] Risk for hip fracture before and after total knee replacement in Sweden
    Vala, C. H.
    Karrholm, J.
    Kanis, J. A.
    Johansson, H.
    Sten, S.
    Sundh, V.
    Karlsson, M.
    Lorentzon, M.
    Mellstrom, D.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (05) : 887 - 895
  • [35] Factors predicting manipulation under anaesthesia after total knee replacement
    Areti, Aruni
    Ratcliff, Terrul
    Perake, Vinayak
    Sambandam, Senthil N.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [36] Patellofemoral kinematics during deep knee flexion after total knee replacement: a computational simulation
    Chang-Hung Huang
    Lin-I Hsu
    Kun-Jhih Lin
    Ting-Kuo Chang
    Cheng-Kung Cheng
    Yung-Chang Lu
    Chen-Sheng Chen
    Chun-Hsiung Huang
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 3047 - 3053
  • [37] Impact of sarcopenia on rehabilitation outcomes after total knee replacement in older adults with knee osteoarthritis
    Liao, Chun-De
    Chen, Hung-Chou
    Huang, Shih-Wei
    Liou, Tsan-Hon
    THERAPEUTIC ADVANCES IN MUSCULOSKELETAL DISEASE, 2021, 13
  • [38] Bilateral Sequential Total Knee Replacement Versus Unilateral Total Knee Replacement in a High Volume Hospital
    Pui-kan, Chan Calvin
    Lee Quun-jid
    Wong Yiu-chung
    Wai Yuk-leung
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2018, 24 : 9 - 11
  • [39] Total knee replacement for severe valgus deformity of the knee
    Yamamoto, S
    Nakata, S
    Takubo, N
    Yamada, K
    JOINT ARTHROPLASTY, 1999, : 330 - 336
  • [40] Total knee replacement with natural rollback
    Wachowski, Martin Michael
    Walde, Tim Alexander
    Balcarek, Peter
    Schuettrumpf, Jan Philipp
    Frosch, Stephan
    Stauffenberg, Caspar
    Frosch, Karl-Heinz
    Fiedler, Christoph
    Fanghaenel, Jochen
    Kubein-Meesenburg, Dietmar
    Naegerl, Hans
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2012, 194 (02) : 195 - 199