High-Field Detection of Biomarkers with Fast Field-Cycling MRI: The Example of Zinc Sensing

被引:9
作者
Boedenler, Markus [1 ]
Malikidogo, Kyangwi P. [2 ]
Morfin, Jean-Francois [2 ]
Aigner, Christoph Stefan [1 ]
Toth, Eva [2 ]
Bonnet, Celia S. [2 ]
Scharfetter, Hermann [1 ]
机构
[1] Graz Univ Technol, Inst Med Engn, Graz, Austria
[2] CNRS, Ctr Biophys Mol, Rue Charles Sadron, F-45071 Orleans 2, France
关键词
contrast agents; fast field-cycling; high-field detection; magnetic resonance imaging; molecular imaging; MAGNETIC-RESONANCE; CONTRAST AGENTS; COMPLEXES; PROBES; COORDINATION; DESIGN; IONS;
D O I
10.1002/chem.201901157
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Many smart magnetic resonance imaging (MRI) probes provide response to a biomarker based on modulation of their rotational correlation time. The magnitude of such MRI signal changes is highly dependent on the magnetic field and the response decreases dramatically at high fields (>2 T). To overcome the loss of efficiency of responsive probes at high field, with fast-field cycling magnetic resonance imaging (FFC-MRI) we exploit field-dependent information rather than the absolute difference in the relaxation rate measured in the absence and in the presence of the biomarker at a given imaging field. We report here the application of fast field-cycling techniques combined with the use of a molecular probe for the detection of Zn2+ to achieve 166 % MRI signal enhancement at 3 T, whereas the same agent provides no detectable response using conventional MRI. This approach can be generalized to any biomarker provided the detection is based on variation of the rotational motion of the probe.
引用
收藏
页码:8236 / 8239
页数:4
相关论文
共 50 条
[41]   The value of high-field MRI (3T) in the assessment of sellar lesions [J].
Pinker, K ;
Ba-Ssalamah, A ;
Wolfsberger, S ;
Mlynarik, V ;
Knosp, E ;
Trattnig, S .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (03) :327-334
[42]   Design of a fast field-cycling magnetic resonance imaging system, characterization and methods for relaxation dispersion measurements around 1.5 T [J].
Chanet, Nicolas ;
Guillot, Genevieve ;
Willoquet, Georges ;
Jourdain, Laurene ;
Dubuisson, Rose-Marie ;
Reganha, Gael ;
de Rochefort, Ludovic .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02)
[43]   High-Field MRI Contrast Agents and their Synergy with Optical Imaging: the Evolution from Single Molecule Probes towards Nano-architectures [J].
Harris, Michael ;
Biju, Silvanose ;
Parac-Vogt, Tatjana N. .
CHEMISTRY-A EUROPEAN JOURNAL, 2019, 25 (61) :13838-13847
[44]   Accuracy of automatic deformable structure propagation for high-field MRI guided prostate radiotherapy [J].
Rasmus Lübeck Christiansen ;
Lars Dysager ;
Anders Smedegaard Bertelsen ;
Olfred Hansen ;
Carsten Brink ;
Uffe Bernchou .
Radiation Oncology, 15
[45]   NITINOL-based actuator for device control even in high-field MRI environment [J].
Kalmar, Marco ;
Boese, Axel ;
Maldonado, Ivan ;
Landes, Rainer ;
Friebe, Michael .
MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2019, 12 :285-296
[46]   Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys [J].
Goense, Jozien ;
Logothetis, Nikos K. ;
Merkle, Hellmut .
MAGNETIC RESONANCE IMAGING, 2010, 28 (08) :1183-1191
[47]   The value of conventional high-field MRI in MS in the light of the McDonald criteria: a literature review [J].
Larsen, L. S. Lunde ;
Larsson, H. B. W. ;
Frederiksen, J. L. .
ACTA NEUROLOGICA SCANDINAVICA, 2010, 122 (03) :149-158
[48]   EARLY CLINICAL AND IMAGING (HIGH-FIELD MRI) DIAGNOSIS OF HALLERVORDEN-SPATZ DISEASE [J].
FELICIANI, M ;
CURATOLO, P .
NEURORADIOLOGY, 1994, 36 (03) :247-248
[49]   Accuracy of automatic deformable structure propagation for high-field MRI guided prostate radiotherapy [J].
Christiansen, Rasmus Lubeck ;
Dysager, Lars ;
Bertelsen, Anders Smedegaard ;
Hansen, Olfred ;
Brink, Carsten ;
Bernchou, Uffe .
RADIATION ONCOLOGY, 2020, 15 (01)
[50]   Cardiac and respiration-induced brain deformations in humans quantified with high-field MRI [J].
Sloots, Jacob Jan ;
Biessels, Geert Jan ;
Zwanenburg, Jaco J. M. .
NEUROIMAGE, 2020, 210