High-Field Detection of Biomarkers with Fast Field-Cycling MRI: The Example of Zinc Sensing

被引:9
作者
Boedenler, Markus [1 ]
Malikidogo, Kyangwi P. [2 ]
Morfin, Jean-Francois [2 ]
Aigner, Christoph Stefan [1 ]
Toth, Eva [2 ]
Bonnet, Celia S. [2 ]
Scharfetter, Hermann [1 ]
机构
[1] Graz Univ Technol, Inst Med Engn, Graz, Austria
[2] CNRS, Ctr Biophys Mol, Rue Charles Sadron, F-45071 Orleans 2, France
关键词
contrast agents; fast field-cycling; high-field detection; magnetic resonance imaging; molecular imaging; MAGNETIC-RESONANCE; CONTRAST AGENTS; COMPLEXES; PROBES; COORDINATION; DESIGN; IONS;
D O I
10.1002/chem.201901157
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Many smart magnetic resonance imaging (MRI) probes provide response to a biomarker based on modulation of their rotational correlation time. The magnitude of such MRI signal changes is highly dependent on the magnetic field and the response decreases dramatically at high fields (>2 T). To overcome the loss of efficiency of responsive probes at high field, with fast-field cycling magnetic resonance imaging (FFC-MRI) we exploit field-dependent information rather than the absolute difference in the relaxation rate measured in the absence and in the presence of the biomarker at a given imaging field. We report here the application of fast field-cycling techniques combined with the use of a molecular probe for the detection of Zn2+ to achieve 166 % MRI signal enhancement at 3 T, whereas the same agent provides no detectable response using conventional MRI. This approach can be generalized to any biomarker provided the detection is based on variation of the rotational motion of the probe.
引用
收藏
页码:8236 / 8239
页数:4
相关论文
共 50 条
[31]   Intracellular Bimodal Nanoparticles Based on Quantum Dots for High-Field MRI at 21.1 T [J].
Rosenberg, Jens T. ;
Kogot, Joshua M. ;
Lovingood, Derek D. ;
Strouse, Geoffrey F. ;
Grant, Samuel C. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) :871-882
[32]   High-permittivity solid ceramic resonators for high-field human MRI [J].
Aussenhofer, S. A. ;
Webb, A. G. .
NMR IN BIOMEDICINE, 2013, 26 (11) :1555-1561
[33]   Control of Mutual Coupling in High-Field MRI Transmit Arrays in the Presence of High-Permittivity Liners [J].
Kordzadeh, Atefeh ;
De Zanche, Nicola .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (09) :3485-3491
[34]   An artificial dielectric slab for ultra high-field MRI: Proof of concept [J].
Vorobyev, Vsevolod ;
Shchelokova, Alena ;
Zivkovic, Irena ;
Slobozhanyuk, Alexey ;
Baena, Juan D. ;
del Risco, Juan P. ;
Abdeddaim, Redha ;
Webb, Andrew ;
Glybovski, Stanislav .
JOURNAL OF MAGNETIC RESONANCE, 2020, 320
[35]   Potential Role of High-Field MRI for Studies in Parkinson's Disease [J].
Schuff, Norbert .
MOVEMENT DISORDERS, 2009, 24 (14) :S684-S690
[36]   High-Field MRI and Mercury Release from Dental Amalgam Fillings [J].
Mortazavi, S. M. J. ;
Neghab, M. ;
Anoosheh, S. M. H. ;
Bahaeddini, N. ;
Mortazavi, G. ;
Neghab, P. ;
Rajaeifard, A. .
INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2014, 5 (02) :101-105
[37]   Gadolinium(III)-loaded nanoparticulate zeolites as potential high-field MRI contrast agents:: Relationship between structure and relaxivity [J].
Csajbók, É ;
Bányai, I ;
Vander Elst, L ;
Muller, RN ;
Zhou, WZ ;
Peters, JA .
CHEMISTRY-A EUROPEAN JOURNAL, 2005, 11 (16) :4799-4807
[38]   Spatially-Integrated Vectorcardiogram: An Enabling Technique for Arrhythmia Cardiac Gating in High-Field MRI [J].
Gregory, Thomas S. ;
Tse, Zion T. .
CIRCULATION, 2013, 128 (22)
[39]   Optimization of high-channel count, switch matrices for multinuclear, high-field MRI [J].
Felder, Jorg ;
Choi, Chang-Hoon ;
Ko, Yunkyoung ;
Shah, N. Jon .
PLOS ONE, 2020, 15 (08)
[40]   Development of High-Field Permanent Magnetic Circuits for NMRI/MRI and Imaging on Mice [J].
Wang, Guangxin ;
Xie, Huantong ;
Hou, Shulian ;
Chen, Wei ;
Yang, Xiuhong .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016