High-Field Detection of Biomarkers with Fast Field-Cycling MRI: The Example of Zinc Sensing

被引:9
作者
Boedenler, Markus [1 ]
Malikidogo, Kyangwi P. [2 ]
Morfin, Jean-Francois [2 ]
Aigner, Christoph Stefan [1 ]
Toth, Eva [2 ]
Bonnet, Celia S. [2 ]
Scharfetter, Hermann [1 ]
机构
[1] Graz Univ Technol, Inst Med Engn, Graz, Austria
[2] CNRS, Ctr Biophys Mol, Rue Charles Sadron, F-45071 Orleans 2, France
关键词
contrast agents; fast field-cycling; high-field detection; magnetic resonance imaging; molecular imaging; MAGNETIC-RESONANCE; CONTRAST AGENTS; COMPLEXES; PROBES; COORDINATION; DESIGN; IONS;
D O I
10.1002/chem.201901157
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Many smart magnetic resonance imaging (MRI) probes provide response to a biomarker based on modulation of their rotational correlation time. The magnitude of such MRI signal changes is highly dependent on the magnetic field and the response decreases dramatically at high fields (>2 T). To overcome the loss of efficiency of responsive probes at high field, with fast-field cycling magnetic resonance imaging (FFC-MRI) we exploit field-dependent information rather than the absolute difference in the relaxation rate measured in the absence and in the presence of the biomarker at a given imaging field. We report here the application of fast field-cycling techniques combined with the use of a molecular probe for the detection of Zn2+ to achieve 166 % MRI signal enhancement at 3 T, whereas the same agent provides no detectable response using conventional MRI. This approach can be generalized to any biomarker provided the detection is based on variation of the rotational motion of the probe.
引用
收藏
页码:8236 / 8239
页数:4
相关论文
共 50 条
  • [21] Update cartilage imaging of the small joints Focus on high-field MRI
    Heiss, R.
    Janka, R.
    Uder, M.
    Nagel, A. M.
    Trattnig, S.
    Roemer, F. W.
    RADIOLOGE, 2019, 59 (08): : 732 - 741
  • [22] Reduction of Inductive Links Between Coils for High-Field MRI Systems
    Li, Lankai
    Cheng, Junsheng
    Qun, He
    Liu, Zhaoquan
    Li, Guochao
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (04)
  • [23] Low-field versus high-field MRI in diagnosing breast disorders
    Pääkkö, E
    Reinikainen, H
    Lindholm, EL
    Rissanen, T
    EUROPEAN RADIOLOGY, 2005, 15 (07) : 1361 - 1368
  • [24] Low-field versus high-field MRI in diagnosing breast disorders
    Eija Pääkkö
    Heli Reinikainen
    Eija-Leena Lindholm
    Tarja Rissanen
    European Radiology, 2005, 15 : 1361 - 1368
  • [25] Metasurface Approach to Generate Homogeneous B1+ Field for High-Field and Ultra-High-Field MRI
    Xue, Chen
    Zhou, Guanglei
    Wong, Alex M. H.
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024, 8 (02): : 155 - 162
  • [26] CT AND HIGH-FIELD MRI IN SEPTIC THROMBOSIS OF THE CAVERNOUS SINUSES
    ELLIE, E
    HOUANG, B
    LOUAIL, C
    LEGRAINLIFERMANN, V
    LAURENT, F
    DROUILLARD, J
    JULIEN, J
    NEURORADIOLOGY, 1992, 34 (01) : 22 - 24
  • [27] Characteristics of symptomatic chronic subdural haematomas on high-field MRI
    M. Kaminogo
    J. Moroki
    A. Ochi
    A. Ichikura
    M. Onizuka
    A. Shibayama
    H. Miyake
    S. Shibata
    Neuroradiology, 1999, 41 : 109 - 116
  • [28] Minimum Stored Energy High-Field MRI Superconducting Magnets
    Tieng, Quang M.
    Vegh, Viktor
    Brereton, Ian M.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (04) : 3645 - 3652
  • [29] Characteristics of symptomatic chronic subdural haematomas on high-field MRI
    Kaminogo, M
    Moroki, J
    Ochi, A
    Ichikura, A
    Onizuka, M
    Shibayama, A
    Miyake, H
    Shibata, S
    NEURORADIOLOGY, 1999, 41 (02) : 109 - 116
  • [30] ECG artifacts during intraoperative high-field MRI scanning
    Birkholz, T
    Schmid, M
    Ninisky, C
    Schüttler, J
    Schmitz, B
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2004, 16 (04) : 271 - 276