Analysis of total corneal astigmatism with a rotating Scheimpflug camera in keratoconus

被引:5
|
作者
Kim, Jinho [1 ]
Whang, Woong-Joo [2 ]
Kim, Hyun-Seung [1 ]
机构
[1] Catholic Univ Korea Korea, Seoul St Marys Hosp, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Dept Ophthalmol, Seoul, South Korea
关键词
CATARACT-SURGERY; ANTERIOR; POWER; SHAPE; EYES; SURFACE; ERROR;
D O I
10.1186/s12886-020-01747-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To analyze mean corneal powers and astigmatisms on anterior, posterior, and total cornea in patients with keratoconus as calculated according to various keratometric measurements using a Scheimpflug camera. Methods: We examined the left eyes of 64 patients (41 males and 23 females; mean age 29.94 +/- 6.63 years) with keratoconus. We measured simulated K (Sim-K), posterior K, true net power (TNP) and four types of total corneal refractive powers (TCRP). We then used the obtained values to analyze mean K, and corneal astigmatism. TCRP were measured at 2.0 +/- 5.0 mm. Results: Mean corneal powers from Sim K, posterior K, and TNP were 49.12 +/- 3.99, - 7.39 +/- 0.79, and 47.78 +/- 4.09 diopters, respectively. For TCRP centered on the pupil, mean K tended to decrease with measurement area (all p < 0.01). While, both mean K and astigmatism measured using TCRP centered on the apex decreased with measurement area (all p < 0.001). TCRP centered on the apex were greater than those centered on the pupil for mean K values calculated using TCRP (all p < 0.001). The proportion of WTR was greatest on the anterior and total cornea. As the measurement area moved to the periphery, the proportion of WTR increased. Conclusions: Mean corneal powers and astigmatisms on total cornea with keratoconus change depending on calculation methods and measurement areas.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Fourier Analysis on Irregular Corneal Astigmatism Using Optical Coherence Tomography in Various Severity Stages of Keratoconus
    Maeno, Sayo
    Koh, Shizuka
    Inoue, Ryota
    Oie, Yoshinori
    Maeda, Naoyuki
    Jhanji, Vishal
    Nishida, Kohji
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 243 : 55 - 65
  • [42] Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis
    Fukuda, Shinichi
    Beheregaray, Simone
    Hoshi, Sujin
    Yamanari, Masahiro
    Lim, Yiheng
    Hiraoka, Takahiro
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (12) : 1554 - 1559
  • [43] Central Corneal Thickness Measurements With Fourier-Domain Optical Coherence Tomography Versus Ultrasonic Pachymetry and Rotating Scheimpflug Camera
    Ishibazawa, Akihiro
    Igarashi, Sho
    Hanada, Kazuomi
    Nagaoka, Taiji
    Ishiko, Satoshi
    Ito, Haruna
    Yoshida, Akitoshi
    CORNEA, 2011, 30 (06) : 615 - 619
  • [44] Agreement of corneal measurements between dual rotating Scheimpflug-Placido system and Placido-based topography device in normal and keratoconus eyes
    Ortiz-Toquero, Sara
    Zuniga, Virginia
    Rodriguez, Guadalupe
    de Juan, Victoria
    Martin, Raul
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) : 1198 - 1206
  • [45] Mapping Corneal Thickness Using Dual-Scheimpflug Imaging at Different Stages of Keratoconus
    Demir, Selim
    Ortak, Huseyin
    Yeter, Volkan
    Alim, Sait
    Sayin, Osman
    Tas, Ufuk
    Sonmez, Baris
    CORNEA, 2013, 32 (11) : 1470 - 1474
  • [46] Evaluation of keratometric and total corneal astigmatism measurements from optical biometers and anterior segment tomographers and mapping to reconstructed corneal astigmatism vector components
    Langenbucher, Achim
    Szentmary, Nora
    Cayless, Alan
    Hoffmann, Peter
    Wendelstein, Jascha
    Pantanelli, Seth
    PLOS ONE, 2025, 20 (01):
  • [47] Prediction of total corneal power in keratoconus using anterior surface data
    Camellin, Umberto
    Ninotta, Ivan
    Latino, Gianluigi
    Alibrandi, Angela
    Aragona, Pasquale
    Roszkowska, Anna M. M.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (03) : 274 - 280
  • [48] Influence factors of estimation errors for total corneal astigmatism using keratometric astigmatism in patients before cataract surgery
    Zheng, Tianyu
    Chen, Zhanghua
    Lu, Yi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01) : 84 - 94
  • [49] Prevalence data for total corneal astigmatism in cataract patients
    Bian, Linbo
    Ma, Baikai
    Sun, Zhengze
    Li, Wenlong
    Liu, Yiyun
    Qin, Rui
    Chen, Jiawei
    Ma, Yunke
    Zhao, Lu
    Qi, Hong
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (10) : 3219 - 3227
  • [50] Comparing surgically induced astigmatism calculated by means of simulated keratometry versus total corneal refractive power
    Garzon, Nuria
    Rodriguez-Vallejo, Manuel
    Carmona, David
    Calvo-Sanz, Jorge A.
    Poyales, Francisco
    Palomino, Carlos
    Zato-Gomez de Liano, Miguel A.
    Fernandez, Joaquin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (05) : 573 - 581