Early fixation failure of locked plating in complex distal femoral fractures: Root causes analysis

被引:4
作者
Hsu, Chun-Liang [1 ,2 ]
Yang, Jui-Jung [1 ,2 ]
Yeh, Tsu-Te [1 ,2 ]
Shen, Hsain-Chung [1 ,2 ]
Pan, Ru-Yu [1 ,2 ]
Wu, Chia-Chun [1 ,2 ]
机构
[1] Triserv Gen Hosp, Dept Orthoped Surg, 325 Cheng Gong Rd,Sect 2, Taipei 114, Taiwan
[2] Natl Def Med Ctr, 325 Cheng Gong Rd,Sect 2, Taipei 114, Taiwan
关键词
Femoral fractures; Fractures; Comminuted; Orthopedics; Risk factors; FEMUR FRACTURES;
D O I
10.1016/j.jfma.2020.06.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Purpose: Orthopaedic Trauma Association (OTA) C-type distal femoral fractures can be very challenging to treat effectively. While locked plating is widely used in the complex distal femoral fracture, failure of locked plate fixation is not uncommon. First, we tried to determine the risk factor related to early failure of multiplanar OTA C-type fracture in the distal femur after fixation with lateral locked plate. Second, we tried to provide a strategy for surgeons to prevent pitfalls of early failure in the complex distal femoral fractures treated with lateral locked plating. Methods: We retrospectively reviewed 44 adults with OTA C-type fractures of the distal femur treated with locked plate fixation between 2010 and 2016 at Tri-Service General Hospital. Average length of follow-up was 27.6 months (range, 12-54 months). Univariate and multivariate logistic regression were used to determine the association of variables on early failure of fixation. A p-value < 0.05 in univariate and multivariate analyses were considered significant. Results: There were six patients experiencing early failure, and the early failure rate was 13.6%. The risk factors associated with early failure of complex distal femoral fracture identified by univariate analysis included sagittal oblique fracture pattern, longer working length and post-operative sagittal malalignment (odds ratio [OR] and 95% confidence intervals [CI]: 90.00 (6.85-1183.33), 0.55 (0.31-0.98) and 8.63 (1.077-69.075) respectively). The multivariate analysis showed only sagittal oblique fracture pattern was associated with early failure [OR: 52.348 (3.06-895.23)]. Conclusion: Sagittal oblique fracture was more likely to result in early postoperative failure. Early recognition of the fracture pattern should be considered to avoid catastrophic results. Copyright (C) 2020, Formosan Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [21] Immediate weight-bearing is safe following lateral locked plate fixation of periprosthetic distal femoral fractures
    Keenan, Oisin J. F.
    Ross, Lauren A.
    Magill, Matthew
    Moran, Matthew
    Scott, Chloe E. H.
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [22] Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures
    Gogna Paritosh
    Mukhopadhyay Reetadyuti
    Singh Amanpreet
    Devgan Ashish
    Arora Sahil
    Batra Amit
    Yadav Sushil Kumar
    中华创伤杂志英文版, 2015, 18 (05) : 279 - 283
  • [23] Very Distal Femoral Periprosthetic Fractures: Replacement Versus Fixation: A Systematic Review
    Rubinger, Luc
    Khalik, Hassaan Abdel
    Gazendam, Aaron
    Wolfstadt, Jesse
    Khoshbin, Amir
    Tushinski, Daniel
    Johal, Herman
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (11) : 573 - 583
  • [24] Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures
    Gogna, Paritosh
    Mukhopadhyay, Reetadyuti
    Singh, Amanpreet
    Devgan, Ashish
    Arora, Sahil
    Batra, Amit
    Yadav, Sushil Kumar
    CHINESE JOURNAL OF TRAUMATOLOGY, 2015, 18 (05) : 279 - 283
  • [25] Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
    Fitzpatrick, Daniel C.
    Doornink, Josef
    Madey, Steven M.
    Bottlang, Michael
    CLINICAL BIOMECHANICS, 2009, 24 (02) : 203 - 209
  • [26] Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation
    Lujan, Trevor J.
    Henderson, Chris E.
    Madey, Steven M.
    Fitzpatrick, Dan C.
    Marsh, J. Lawrence
    Bottlang, Michael
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (03) : 156 - 162
  • [27] Dual plating for fixation failure of the distal femur: Finite element analysis and a clinical series
    Jitprapaikulsarn, Surasak
    Chantarapanich, Nattapon
    Gromprasit, Arthit
    Mahaisavariya, Chantas
    Sukha, Kritsada
    Chiawchan, Suwichote
    MEDICAL ENGINEERING & PHYSICS, 2023, 111
  • [28] Hybrid locked medial plating in dual plate fixation optimizes the healing of comminuted distal femur fractures: A retrospective cohort study
    Liu, Jun-Feng
    Zhou, Zi-Fei
    Hou, Xiao-Dong
    Chen, Yi-Xing
    Zheng, Long-Po
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (06): : 1614 - 1620
  • [29] PROXIMAL HUMERAL LOCKING PLATE: A VIABLE ALTERNATIVE FOR FIXATION OF DISTAL FEMORAL FRACTURES IN CHILDREN
    Valenza, Weverley Rubele
    Soni, Jamil Faissal
    Schuta Bodanese, Bruno Henrique
    Rossetto, Deivide Mateus
    De Paula Kosovits, Francisco Guilherme
    Pedroni Cordeiro, Pedro Ivo
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31
  • [30] Distal femoral fractures: A comparison between single lateral plate fixation and a combined femoral nail and plate fixation
    Garala, Kanai
    Ramoutar, Darryl
    Li, James
    Syed, Farhan
    Arastu, Mateen
    Ward, Jayne
    Patil, Sunit
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 634 - 639