Early fixation failure of locked plating in complex distal femoral fractures: Root causes analysis

被引:4
|
作者
Hsu, Chun-Liang [1 ,2 ]
Yang, Jui-Jung [1 ,2 ]
Yeh, Tsu-Te [1 ,2 ]
Shen, Hsain-Chung [1 ,2 ]
Pan, Ru-Yu [1 ,2 ]
Wu, Chia-Chun [1 ,2 ]
机构
[1] Triserv Gen Hosp, Dept Orthoped Surg, 325 Cheng Gong Rd,Sect 2, Taipei 114, Taiwan
[2] Natl Def Med Ctr, 325 Cheng Gong Rd,Sect 2, Taipei 114, Taiwan
关键词
Femoral fractures; Fractures; Comminuted; Orthopedics; Risk factors; FEMUR FRACTURES;
D O I
10.1016/j.jfma.2020.06.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Purpose: Orthopaedic Trauma Association (OTA) C-type distal femoral fractures can be very challenging to treat effectively. While locked plating is widely used in the complex distal femoral fracture, failure of locked plate fixation is not uncommon. First, we tried to determine the risk factor related to early failure of multiplanar OTA C-type fracture in the distal femur after fixation with lateral locked plate. Second, we tried to provide a strategy for surgeons to prevent pitfalls of early failure in the complex distal femoral fractures treated with lateral locked plating. Methods: We retrospectively reviewed 44 adults with OTA C-type fractures of the distal femur treated with locked plate fixation between 2010 and 2016 at Tri-Service General Hospital. Average length of follow-up was 27.6 months (range, 12-54 months). Univariate and multivariate logistic regression were used to determine the association of variables on early failure of fixation. A p-value < 0.05 in univariate and multivariate analyses were considered significant. Results: There were six patients experiencing early failure, and the early failure rate was 13.6%. The risk factors associated with early failure of complex distal femoral fracture identified by univariate analysis included sagittal oblique fracture pattern, longer working length and post-operative sagittal malalignment (odds ratio [OR] and 95% confidence intervals [CI]: 90.00 (6.85-1183.33), 0.55 (0.31-0.98) and 8.63 (1.077-69.075) respectively). The multivariate analysis showed only sagittal oblique fracture pattern was associated with early failure [OR: 52.348 (3.06-895.23)]. Conclusion: Sagittal oblique fracture was more likely to result in early postoperative failure. Early recognition of the fracture pattern should be considered to avoid catastrophic results. Copyright (C) 2020, Formosan Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [1] Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort
    Hoffmann, Martin F.
    Jones, Clifford B.
    Sietsema, Debra L.
    Tornetta, Paul, III
    Koenig, Scott J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2013, 8
  • [2] The outcome of Polyax Locked Plating System for fixation distal femoral non-implant related and periprosthetic fractures
    Lampropoulou-Adamidou, Kalliopi
    Tosounidis, Theodoros H.
    Kanakaris, Nikolaos K.
    Ekkernkamp, Axel
    Wich, Michael
    Giannoudis, Peter V.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S18 - S24
  • [3] Double Plating Fixation vs Distal Femoral Replacement in the Management of Distal Femoral Fractures in Geriatric Patients
    Gendya, Amr Gamaleldin Mahmoud Khalil
    El-Zaher, El-Zaher Hassan
    Zakaria, Zeiad Mohamed
    Awad, Mohamed El Sayed
    Metwaly, Radwan Gamal Eldeen Abdelhamid
    ARTHROPLASTY TODAY, 2023, 20
  • [4] Contradictory working length effects in locked plating of the distal and middle femoral fractures a biomechanical study
    Chao, Ching-Kong
    Chen, You-Lin
    Wu, Jian-Ming
    Lin, Chen-Huei
    Chuang, Ting-Yu
    Lin, Jinn
    CLINICAL BIOMECHANICS, 2020, 80
  • [5] Non-union in lateral locked plating for distal femoral fractures: A systematic review
    Wang, Michael Tianfeng
    An, Vincent V. G.
    Sivakumar, Brahman Shankar
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 1790 - 1794
  • [6] Equivalent mortality and complication rates following periprosthetic distal femur fractures managed with either lateral locked plating or a distal femoral replacement
    Hoellwarth, Jason S.
    Fourman, Mitchell S.
    Crossett, Lawrence
    Goodman, Mark
    Siska, Peter
    Moloney, Gele B.
    Tarkin, Ivan S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (02): : 392 - 397
  • [7] The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures
    Weaver, Michael J.
    Chaus, George W.
    Masoudi, Aidin
    Momenzadeh, Kaveh
    Mohamadi, Amin
    Rodriguez, Edward K.
    Vrahas, Mark S.
    Nazarian, Ara
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [8] Distal femoral fractures: A review of fixation methods
    Forster, MC
    Komarsamy, B
    Davison, JN
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (02): : 97 - 108
  • [9] Early rehabilitation following less invasive surgical stabilisation plate fixation for distal femoral fractures
    Smith, T. O.
    Hedges, C.
    MacNair, R.
    Schankat, K.
    PHYSIOTHERAPY, 2009, 95 (02) : 61 - 75
  • [10] Biphasic plating improves the mechanical performance of locked plating for distal femur fractures
    Epari, Devakara R.
    Gurung, Roshan
    Hofmann-Fliri, Ladina
    Schwyn, Ronald
    Schuetz, Michael
    Windolf, Markus
    JOURNAL OF BIOMECHANICS, 2021, 115