Assessment of Prosthesis Alignment after Revision Total Knee Arthroplasty Using EOS 2D and 3D Imaging: A Reliability Study

被引:26
|
作者
Meijer, Marrigje F. [1 ]
Boerboom, Alexander L. [1 ]
Stevens, Martin [1 ]
Bulstra, Sjoerd K. [1 ]
Reininga, Inge H. F. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthopaed, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Trauma Surg, Groningen, Netherlands
来源
PLOS ONE | 2014年 / 9卷 / 09期
关键词
LOWER-EXTREMITY; REPRODUCIBILITY; REHABILITATION; AGREEMENT; POSITION; ROTATION; SYSTEM;
D O I
10.1371/journal.pone.0104613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). Methods: Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. Results: Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00 degrees and 1.61 degrees existed between 2D and 3D measurements. Conclusions: EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images
    Robertson, Emma L.
    Hengherr, Martin
    Amsler, Felix
    Hirschmann, Michael T.
    Mathis, Dominic T.
    SKELETAL RADIOLOGY, 2021, 50 (07) : 1389 - 1397
  • [42] A Control Software of Gated Imaging Lab(GIL) for 2D/3D Range-gated Imaging
    Liu, Xiaoquan
    Wang, Xinwei
    Cao, Yinan
    Fan, Songtao
    Zhou, Yan
    2014 2ND INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2014, : 1017 - 1021
  • [43] From a circle to a sphere: the ultrasound imaging of ovarian follicle with 2D and 3D technology
    Re, Claudia
    Renzini, Mario Mignini
    Rodriguez, Amelia
    Dal Canto, Mariabeatrice
    Buccheri, Matteo
    Sacchi, Sandro
    Bartolucci, Silvia
    Fadini, Rubens
    La Marca, Antonio
    GYNECOLOGICAL ENDOCRINOLOGY, 2019, 35 (03) : 184 - 189
  • [44] Lateral shift of the femoral condyle after total knee arthroplasty: simulation using 2D-templates of the medial pivot design on knee radiographs of young Japanese patients
    Nakajima, Arata
    Sonobe, Masato
    Akatsu, Yorikazu
    Yamada, Manabu
    Yamamoto, Keiichiro
    Saito, Junya
    Norimoto, Masaki
    Koyama, Keita
    Taniguchi, Shinji
    Takahashi, Hiroshi
    Aoki, Yasuchika
    Suguro, Toru
    Nakagawa, Koichi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [45] 2D/3D mixed display based on integral imaging and a switchable diffuser element
    Ren, Hui
    Xing, Yan
    Zhang, Han-Le
    Li, Qiang
    Wang, Lei
    Deng, Huan
    Wang, Qiong-Hua
    APPLIED OPTICS, 2019, 58 (34) : G276 - G281
  • [46] 3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [47] 3D/2D convertible projection-type integral imaging using concave half mirror array
    Hong, Jisoo
    Kim, Youngmin
    Park, Soon-gi
    Hong, Jong-Ho
    Min, Sung-Wook
    Lee, Sin-Doo
    Lee, Byoungho
    OPTICS EXPRESS, 2010, 18 (20): : 20628 - 20637
  • [48] Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol
    Edgar A Wakelin
    Linda Tran
    Joshua G Twiggs
    Willy Theodore
    Justin P Roe
    Michael I Solomon
    Brett A Fritsch
    Brad P Miles
    Journal of Orthopaedic Surgery and Research, 13
  • [49] Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol
    Wakelin, Edgar A.
    Tran, Linda
    Twiggs, Joshua G.
    Theodore, Willy
    Roe, Justin P.
    Solomon, Michael I.
    Fritsch, Brett A.
    Miles, Brad P.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [50] 3D Object Recognition Using Fuzzy Mathematical Modeling of 2D Images
    Sheta, Alaa F.
    Baareh, Abdelkarim
    Ai-Batah, Mohammad
    2012 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2012, : 278 - 283