Assessment of Prosthesis Alignment after Revision Total Knee Arthroplasty Using EOS 2D and 3D Imaging: A Reliability Study

被引:26
|
作者
Meijer, Marrigje F. [1 ]
Boerboom, Alexander L. [1 ]
Stevens, Martin [1 ]
Bulstra, Sjoerd K. [1 ]
Reininga, Inge H. F. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthopaed, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Trauma Surg, Groningen, Netherlands
来源
PLOS ONE | 2014年 / 9卷 / 09期
关键词
LOWER-EXTREMITY; REPRODUCIBILITY; REHABILITATION; AGREEMENT; POSITION; ROTATION; SYSTEM;
D O I
10.1371/journal.pone.0104613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). Methods: Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. Results: Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00 degrees and 1.61 degrees existed between 2D and 3D measurements. Conclusions: EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] 2D/3D convertible display with enhanced 3D viewing region based on integral imaging
    Park, Soon-gi
    Song, Byoung-Sub
    Min, Sung-Wook
    STEREOSCOPIC DISPLAYS AND APPLICATIONS XXI, 2010, 7524
  • [22] Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D/3D imaging system
    Somoskeoey, Szabolcs
    Tunyogi-Csapo, Miklos
    Bogyo, Csaba
    Illes, Tamas
    SPINE JOURNAL, 2012, 12 (11) : 1052 - 1059
  • [23] Precise 2D and 3D Fluoroscopic Imaging by Using an FMCW Millimeter-Wave Radar
    Wang, Yaheng
    Su, Jie
    Fukuda, Taiga
    Tonouchi, Masayoshi
    Murakami, Hironaru
    IEEE ACCESS, 2023, 11 : 84027 - 84034
  • [24] Preoperative difference between 2D and 3D planning correlates with difference between planned and achieved surgical correction in patient-specific instrumented total knee arthroplasty
    Pfluger, Patrick
    Pedrazzini, Alberto
    Jud, Lukas
    Vlachopoulos, Lazaros
    Hodel, Sandro
    Fucentese, Sandro F.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2025, 12 (01)
  • [25] Bi-sided integral imaging with 2D/3D convertibility using scattering polarizer
    Yeom, Jiwoon
    Hong, Keehoon
    Park, Soon-gi
    Hong, Jisoo
    Min, Sung-Wook
    Lee, Byoungho
    OPTICS EXPRESS, 2013, 21 (25): : 31189 - 31200
  • [26] 2D Manual vs 3D Automated Assessment of Alignment in Normal and Charcot-Marie-Tooth Cavovarus Feet Using Weightbearing CT
    Sangoi, Dhrumin
    Ranjit, Srinath
    Bernasconi, Alessio
    Cullen, Nicholas
    Patel, Shelain
    Welck, Matthew
    Malhotra, Karan
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (07) : 973 - 982
  • [27] Assessment of accuracy and precision of 3D reconstruction of unicompartmental knee arthroplasty in upright position using biplanar radiography
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Hosseini, Ali
    Liow, Ming Han Lincoln
    Torriani, Martin
    Li, Guoan
    Kwon, Young-Min
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (07) : 633 - 638
  • [28] Could surgical transepicondylar axis be identified accurately in preoperative 3D planning for total knee arthroplasty? A reproducibility study based on 3D-CT
    Lei, Kai
    Liu, Li Ming
    Luo, Jiang Ming
    Ma, Chao
    Feng, Qing
    Yang, Liu
    Guo, Lin
    ARTHROPLASTY, 2022, 4 (01)
  • [29] Reliability and correlation analysis of computed methods to convert conventional 2D radiological hindfoot measurements to a 3D setting using weightbearing CT
    Burssens, A.
    Peeters, J.
    Peiffer, M.
    Marien, R.
    Lenaerts, T.
    Vandeputte, G.
    Victor, J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (12) : 1999 - 2008
  • [30] Quality and Reliability of 2D and 3D Clinical Photographs in Plastic Surgery: A Scoping Review
    Tian, William M.
    Fimbres, Denisse C. Porras
    Tran, Melissa M.
    Zeng, Steven L.
    Gnaedinger, Anika G.
    Kaplan, Samantha
    Marcus, Jeffrey R.
    Patel, Ashit
    AESTHETIC PLASTIC SURGERY, 2025,