Experimental Evaluation of a New Antithrombogenic Stent Using Ion Beam Surface Modification

被引:6
作者
Sugita, Yoichi [1 ,2 ,3 ]
Suzuki, Yoshiaki [4 ]
Someya, Kenji [4 ]
Ogawa, Akira [5 ]
Furuhata, Hiroshi [2 ]
Miyoshi, Shinichiro [3 ]
Motomura, Tadashi
Miyamoto, Hiroshi
Igo, Stephen
Nose, Yukihiko
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[2] Jikei Univ, Sch Med, Tokyo, Japan
[3] Dokkyo Univ, Sch Med, Mibu, Tochigi, Japan
[4] RIKEN, Saitama, Japan
[5] ACTMENT Co Ltd, Saitama, Japan
关键词
Coronary stent; Cerebral stent; Ion beam surface modification; Neointima; Collagen; DRUG-ELUTING STENTS; PLASMA-PROTEIN ADSORPTION; SELF-EXPANDING STENTS; CELL ATTACHMENT; CLINICAL-OUTCOMES; LATE THROMBOSIS; ADHESION; COLLAGEN; IMPLANTATION; ARTERY;
D O I
10.1111/j.1525-1594.2009.00747.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new antithrombogenic stent using ion beam surface modification nanotechnology was evaluated. The ion stent is being developed to inhibit acute and chronic stent-related thrombosis. Thirty self-expanding mesh stents were fabricated from Ti-Ni metal wires with a dimension of 4 mm (diameter) x 25 mm (length) x 0.15 mm (thickness). Twenty stents were coated with type I collagen and irradiated with a He+ ion beam at an energy of 150 keV with fluences of 1 x 10(14) ions/cm(2) (ion stent group). Ten stents had no treatment (non-ion stent group). The self-expanding stents were implanted into the right and left peripheral femoral arteries of 15 beagle dogs (vessel diameter approximately 3 mm) via a 6Fr catheter under fluoroscopic guidance. Heparin (100 units/kg) was administered intravenously before implantation. Following stent implantation, no antiplatelet or anticoagulant drugs were administered. The 1-month patency rate for the non-ion stent group was 10% (1/10), and for the ion stent group it was 80% (16/20) with no anticoagulant or antiplatelet drugs given after stent implantation (P = 0.0004 by Fisher's exact test). Ten stents remain patent after 2 years in vivo with no anticoagulant or antiplatelet drugs. These results indicate that He+ ion-implanted collagen-coated Ti-Ni self-expanding stents have excellent antithrombogenicity and biocompatibility. This ion stent is promising for coronary and cerebral stent applications.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 69 条
  • [1] Analysis of 36 reported cases of late thrombosis in drug-eluting stents placed in coronary arteries
    Artang, Ramin
    Dieter, Robert S.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08) : 1039 - 1043
  • [2] Late in-stent thrombosis following carotid angioplasty and stenting
    Buhk, JH
    Wellmer, A
    Knauth, M
    [J]. NEUROLOGY, 2006, 66 (10) : 1594 - 1596
  • [3] CAMENZIND E, 2006, WORLD C CARD 2006 BA
  • [4] Distal embolization after stenting of the vertebral artery: Diffusion-weighted magnetic resonance imaging findings
    Canyigit, Murat
    Arat, Anil
    Cil, Barbaros E.
    Turkbey, Baris
    Saatci, Isil
    Cekirge, Saruhan
    Balkanci, Ferhun
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 189 - 195
  • [5] Chaturvedi S, 2001, STROKE, V32, P2700
  • [6] The role of antiplatelet therapy in carotid stenting for ischemic stroke prevention
    Chaturvedi, Seemant
    Yadav, Jay S.
    [J]. STROKE, 2006, 37 (06) : 1572 - 1577
  • [7] Cell shape provides global control of focal adhesion assembly
    Chen, CS
    Alonso, JL
    Ostuni, E
    Whitesides, GM
    Ingber, DE
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 307 (02) : 355 - 361
  • [8] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [9] Engineering cell adhesive surfaces that direct integrin α5β1 binding using a recombinant fragment of fibronectin
    Cutler, SM
    García, AJ
    [J]. BIOMATERIALS, 2003, 24 (10) : 1759 - 1770
  • [10] Beyond restenosis - Five-year clinical outcomes from second-generation coronary stent trials
    Cutlip, DE
    Chhabra, AG
    Baim, DS
    Chauhan, MS
    Marulkar, S
    Massaro, J
    Bakhai, A
    Cohen, DJ
    Kuntz, RE
    Ho, KKL
    [J]. CIRCULATION, 2004, 110 (10) : 1226 - 1230