Critical seismic incidence angle of transmission tower based on shaking table tests

被引:7
|
作者
Tian, Li [1 ]
Dong, Xu [1 ]
Pan, Haiyang [1 ]
Gao, Guodong [1 ]
Xin, Aiqiang [1 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
UHV transmission tower-line system; reduced-scale model; shaking table test; critical seismic incidence angle; approximation method; LINE SYSTEM; RESPONSE ANALYSIS; FAILURE ANALYSIS; EARTHQUAKE; COLLAPSE; IDENTIFICATION; PERFORMANCE; VIBRATION; SITE;
D O I
10.12989/sem.2020.76.2.251
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.
引用
收藏
页码:251 / 267
页数:17
相关论文
共 50 条
  • [1] Shaking table test on 1000 kV angle steel transmission tower
    Xie, Qiang
    Bai, Jie
    Xue, Songtao
    Qin, Qingzhi
    Dianwang Jishu/Power System Technology, 2013, 37 (01): : 58 - 64
  • [2] The critical angle of seismic incidence of transmission tower-line system based on wavelet energy method
    Tian, Li
    Dong, Xu
    Pan, Haiyang
    He, Xiaoyu
    EARTHQUAKES AND STRUCTURES, 2019, 17 (04) : 387 - 398
  • [3] Seismic fragility analysis of telecommunication cabinets based on shaking table tests
    Shang, Qingxue
    Han, Di
    Sun, Guoliang
    Ji, Shuqiang
    Zuo, Haopeng
    Wang, Tao
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2022, 54 (05): : 57 - 63
  • [4] Shaking table test and seismic behavior of Ningbo Hengda Tower
    Zhao, Bin
    Lin, Yinjia
    Li, Xin
    Zhou, Ying
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2023, 32 (01):
  • [5] Effects of Inclination on the Seismic Performance of Chinese Historical Masonry Tower Identified through Shaking Table Tests
    Xu, Dunfeng
    Xie, Qifang
    Zhang, Yun
    Hao, Wenming
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (06) : 1458 - 1481
  • [6] Shaking-table tests of seismic responses of slender intake tower-hoist chamber systems
    Zhang, Hanyun
    Jiang, Cai
    Liu, Shuming
    Zhang, Liaojun
    Wang, Chen
    Zhang, Yunjuan
    ENGINEERING STRUCTURES, 2021, 242
  • [7] Effect of Slope Angle on Seismic Response of Unreinforced and Reinforced Soil Slopes in Shaking Table Tests
    Srilatha N.
    Latha G.M.
    Puttappa C.G.
    Indian Geotechnical Journal, 2017, 47 (3) : 326 - 337
  • [8] Seismic property of a large section tunnel based on shaking table model tests
    Guan Zhen-chang
    Gong Zhen-feng
    Luo Zhi-bin
    Chen Ren-chun
    He Chuan
    ROCK AND SOIL MECHANICS, 2016, 37 (09) : 2553 - 2560
  • [9] Seismic Fragility Analysis of Freestanding Hospital Cabinets Based on Shaking Table Tests
    Shang, Qingxue
    Li, Jichao
    Du, Chunbo
    Wang, Tao
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (08) : 1993 - 2012
  • [10] The seismic responses and seismic properties of large section mountain tunnel based on shaking table tests
    Guan, Zhenchang
    Zhou, Yi
    Gou, Xiaodong
    Huang, Hongwei
    Wu, Xuezhen
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 90 : 383 - 393