Mesenteric circulation: Three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique

被引:58
作者
Shirkhoda, A
Konez, O
Shetty, AN
Bis, KG
Ellwood, RA
Kirsch, MJ
机构
[1] Department of Diagnostic Radiology, William Beaumont Hospital, Royal Oak, MI 48073
关键词
arteries; mesenteric; intestines; MR; magnetic resonance (MR); vascular studies; portal vein; veins;
D O I
10.1148/radiology.202.1.8988220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the mesenteric circulation with magnetic resonance (MR) angiography, the authors examined 16 individuals (12 patients, four volunteers) with a gadolinium-enhanced, breath-hold, fat-saturated, multiecho, three-dimensional, gradient-echo sequence. Twenty examinations were performed. Grades of 3 or 4 (on a five-point scale [4 = best seen, 0 = not seen]) were applicable to 17 (85%) of 20 MR angiograms obtained in superior mesenteric artery trunks, 15 (75%) in celiac arteries, five (25%) in inferior mesenteric arteries; 15 (75%) of first-order branching, 12 (60%) of second-order branching, and 10 (50%) of third-order branching; 17 (85%) in superior mesenteric veins; and 17 (85%) in portal veins. MR angiography with this technique depicted the mesenteric arterial and venous circulation and the portal vein with excellent resolution in a short time.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 50 条
[21]   Gadolinium-enhanced breathhold three-dimensional time-of-flight renal MR angiography in the evaluation of potential renal donors [J].
Nelson, HA ;
Gilfeather, M ;
Holman, JM ;
Nelson, EW ;
Yoon, HC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (02) :175-181
[22]   Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries [J].
Lee, VS ;
Rofsky, NM ;
Krinsky, GA ;
Stemerman, DH ;
Weinreb, JC .
RADIOLOGY, 1999, 211 (01) :69-78
[23]   Renal arteries: Optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold [J].
Schoenberg, SO ;
Bock, M ;
Knopp, MV ;
Essig, M ;
Laub, G ;
Hawighorst, H ;
Zuna, I ;
Kallinowski, F ;
van Kaick, G .
RADIOLOGY, 1999, 211 (03) :667-679
[24]   Gadolinium-enhanced MR angiography of the lower extremity arteries with on automated table-feed technique. [J].
Lenhart, M ;
Djavidani, B ;
Völk, M ;
Strotzer, M ;
Manke, C ;
Requardt, M ;
Nitz, WR ;
Kasprzak, P ;
Feuerbach, S ;
Link, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (06) :442-449
[25]   Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography [J].
De Cobelli, F ;
Venturini, M ;
Vanzulli, A ;
Sironi, S ;
Salvioni, M ;
Angeli, E ;
Scifo, P ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
Del Maschio, A .
RADIOLOGY, 2000, 214 (02) :373-380
[26]   Carotid artery stenosis, occlusion, and pseudo-occlusion: First-pass, gadolinium-enhanced, three-dimensional MR angiography - Preliminary study [J].
Remonda, L ;
Heid, O ;
Schroth, G .
RADIOLOGY, 1998, 209 (01) :95-102
[27]   HEPATIC HEMANGIOMAS - A MULTIINSTITUTIONAL STUDY OF APPEARANCE ON T2-WEIGHTED AND SERIAL GADOLINIUM-ENHANCED GRADIENT-ECHO MR-IMAGES [J].
SEMELKA, RC ;
BROWN, ED ;
ASCHER, SM ;
PATT, RH ;
BAGLEY, AS ;
LI, W ;
EDELMAN, RR ;
SHOENUT, JP ;
BROWN, JJ .
RADIOLOGY, 1994, 192 (02) :401-406
[28]   Spinal dural arteriovenous fistula localization with a technique of first-pass gadolinium-enhanced MR angiography: Initial experience [J].
Farb, RI ;
Kim, JK ;
Willinsky, RA ;
Montanera, WJ ;
terBrugge, K ;
Derbyshire, JA ;
van Dijk, JMC ;
Wright, GA .
RADIOLOGY, 2002, 222 (03) :843-850
[29]   Crohn disease with endoscopic correlation: Single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging [J].
Low, RN ;
Sebrechts, CP ;
Politoske, DA ;
Bennett, MT ;
Flores, S ;
Snyder, RJ ;
Pressman, JH .
RADIOLOGY, 2002, 222 (03) :652-660
[30]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710