To evaluate the mesenteric circulation with magnetic resonance (MR) angiography, the authors examined 16 individuals (12 patients, four volunteers) with a gadolinium-enhanced, breath-hold, fat-saturated, multiecho, three-dimensional, gradient-echo sequence. Twenty examinations were performed. Grades of 3 or 4 (on a five-point scale [4 = best seen, 0 = not seen]) were applicable to 17 (85%) of 20 MR angiograms obtained in superior mesenteric artery trunks, 15 (75%) in celiac arteries, five (25%) in inferior mesenteric arteries; 15 (75%) of first-order branching, 12 (60%) of second-order branching, and 10 (50%) of third-order branching; 17 (85%) in superior mesenteric veins; and 17 (85%) in portal veins. MR angiography with this technique depicted the mesenteric arterial and venous circulation and the portal vein with excellent resolution in a short time.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 50 条
  • [1] Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels
    Gilfeather, M
    Holland, GA
    Siegelman, ES
    Schanll, MD
    Axel, L
    Carpenter, JP
    Golden, MA
    RADIOGRAPHICS, 1997, 17 (02) : 423 - 432
  • [2] Gadolinium-enhanced breath-hold three-dimensional MR angiography of the portal vein: Value of the magnetization-prepared rapid acquisition gradient-echo sequence
    Yamashita, Y
    Mitsuzaki, K
    Miyazaki, T
    Namimoto, T
    Sumi, S
    Urata, J
    Abe, Y
    Ogata, I
    Takahashi, M
    RADIOLOGY, 1996, 201 (01) : 283 - 288
  • [3] Three-dimensional gadolinium-enhanced MR angiography: Applications for abdominal imaging
    Glockner, JF
    RADIOGRAPHICS, 2001, 21 (02) : 357 - 370
  • [4] Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    Davis, CP
    Hany, TF
    Wildermuth, S
    Schmidt, M
    Debatin, JF
    RADIOGRAPHICS, 1997, 17 (05) : 1061 - 1077
  • [5] Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging
    Krinsky, GA
    Rofsky, NM
    DeCorato, DR
    Weinreb, JC
    Earls, JP
    Flyer, MA
    Galloway, AC
    Colvin, SB
    RADIOLOGY, 1997, 202 (01) : 183 - 193
  • [6] Gadolinium-enhanced three-dimensional MR angiography of Takayasu arteritis
    Nastri, MV
    Baptista, LPS
    Baroni, RH
    Blasbalg, R
    de Avila, LF
    Leite, CC
    de Castro, CC
    Cerri, GG
    RADIOGRAPHICS, 2004, 24 (03) : 773 - 786
  • [7] Pulmonary arteriovenous malformations: Three-dimensional gadolinium-enhanced MR angiography - Initial experience
    Maki, DD
    Siegelman, ES
    Roberts, DA
    Baum, RA
    Gefter, WB
    RADIOLOGY, 2001, 219 (01) : 243 - 246
  • [8] Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography
    Goldfarb, JW
    Edelman, RR
    RADIOLOGY, 1998, 206 (03) : 830 - 834
  • [9] Intracranial aneurysms:: Detection with gadolinium-enhanced dynamic three-dimensional MR angiography -: Initial results
    Metens, T
    Rio, F
    Balériaux, D
    Roger, T
    David, P
    Rodesch, G
    RADIOLOGY, 2000, 216 (01) : 39 - 46
  • [10] Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation
    Earls, JP
    DeSena, S
    Bluemke, DA
    RADIOLOGY, 1998, 209 (03) : 844 - 849