A method for multichannel dosimetry with EBT3 radiochromic films

被引:33
作者
Perez Azorin, Jose Fernando [1 ]
Ramos Garcia, Luis Isaac [2 ]
Marti-Climent, Josep M. [3 ]
机构
[1] Hosp Univ Cruces, Dept Med Phys, Baracaldo 48903, Bizkaia, Spain
[2] Univ Navarra, Dept Oncol, Univ Navarra Clin, Pamplona 31008, Navarre, Spain
[3] Univ Navarra, Dept Nucl Med, Univ Navarra Clin, Pamplona 31008, Navarre, Spain
关键词
radiochromic films; multichannel dosimetry; IMRT verification; QUANTITATIVE-EVALUATION; GAFCHROMIC EBT2; CALIBRATION; SCANNERS; THERAPY; PHOTON; RANGE;
D O I
10.1118/1.4871622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An improved method for multichannel dosimetry is presented. This method explicitly takes into account the information provided by the unexposed image of the film. Methods: The method calculates the dose by applying a couple of perturbations to the scanned dose, one dependent and the other independent on the color channel. The method has been compared with previous multichannel and two single channel methods (red and green) against measurements using two different tests: first, five percentage depth dose profiles covering a wide range of doses; second, the dose map perpendicular to the beam axis for a 15 x 15 cm(2) square field. Finally, the results of 30 IMRT quality assurances tests are presented. All tests have been evaluated using the gamma analysis. Results: The coefficient of variation was found to be similar for all methods in a wide range of doses. The results of the proposed method are more in agreement with the experimental measurements and with the treatment planning system. Furthermore, the differences in the mean gamma pass rates are statistically significant. Conclusions: The improved multichannel dosimetric method is able to remove many of the common disturbances usually present in radiochromic films and improves the gamma analysis results compared with the other three methods. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337
  • [22] Alternate calibration method of radiochromic EBT3 film for quality assurance verification of clinical radiotherapy treatments
    Park, Soah
    Kang, Sei-Kwon
    Cheong, Kwang-Ho
    Hwang, Taejin
    Yoon, Jai-Woong
    Koo, Taeryool
    Han, Tae Jin
    Kim, Haeyoung
    Lee, Me Yeon
    Bae, Hoonsik
    Kim, Kyoung Ju
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (02) : 248 - 252
  • [23] Precise EBT3 Gafchromic film dosimetry for Grid therapy
    Gholami, Somayeh
    Nedaie, Hassan Ali
    Meigooni, Ali S.
    RADIATION MEASUREMENTS, 2019, 121 : 69 - 76
  • [24] A novel method for EBT3 Gafchromic films read-out at high dose levels
    Vaiano, Patrizio
    Consales, Marco
    Casolaro, Pierluigi
    Campajola, Luigi
    Fienga, Francesco
    Di Capua, Francesco
    Breglio, Giovanni
    Buontempo, Salvatore
    Cutolo, Antonello
    Cusano, Andrea
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 77 - 84
  • [25] A new analytical model for the response curve in megavoltage photon beams of the radiochromic EBT3 films measured with flatbed scanners
    Rodriguez, Cesar
    Garcia-Pinto, Diego
    Carlos Martinez, Luis
    Lopez-Fernandez, Alfonso
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (08):
  • [26] Absolute dose calibration of EBT3 Gafchromic films
    Campajola, L.
    Casolaro, P.
    Di Capua, F.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [27] Enhanced dosimetry procedures and assessment for EBT2 radiochromic film
    Mayer, Rulon R.
    Ma, Fuhwa
    Chen, Yu
    Miller, Rachel I.
    Belard, Arnaud
    McDonough, James
    O'Connell, John J.
    MEDICAL PHYSICS, 2012, 39 (04) : 2147 - 2155
  • [28] The Multigaussian method: a new approach to mitigating spatial heterogeneities with multichannel radiochromic film dosimetry
    Mendez, I
    Polsak, A.
    Hudej, R.
    Casar, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (17)
  • [29] Selection of gamma analysis acceptance criteria in IMRT QA using Gafchromic EBT3 film dosimetry
    Khan, Muhammad Isa
    Shakil, Muhammad
    Tahir, Muhammad Bilal
    Rafique, Muhammad
    Iqbal, Tahir
    Zahoor, Aliza
    Rehman, Jalil Ur
    Iqbal, Khalid
    Chow, James C. L.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 127 - 131
  • [30] Radiochromic EBT2 film dosimetry for low-energy protontherapy
    Angellier, G.
    Gautier, M.
    Herault, J.
    MEDICAL PHYSICS, 2011, 38 (11) : 6171 - 6177