Sensor molecules for silver(I)-selective membranes based on mono- to quadri-dentate podands

被引:39
作者
Chung, S
Kim, W
Park, SB
Yoon, I
Lee, SS
Sung, DD
机构
[1] INJE UNIV,DEPT CHEM,KIMHAE 621749,SOUTH KOREA
[2] GYEONGSANG NATL UNIV,DEPT CHEM,CHINJU 660701,SOUTH KOREA
[3] DONG A UNIV,DEPT CHEM,PUSAN 604714,SOUTH KOREA
关键词
D O I
10.1039/a701259d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A series of podands containing nitrogen and sulfur atoms are utilized as sensing components to prepare Ag+-selective polymeric membrane electrodes whose characteristics are dependent on the structure of each podand used.
引用
收藏
页码:965 / 966
页数:2
相关论文
共 13 条
[1]   COMPARATIVE-STUDY OF POLYETHER-TYPE NEUTRAL CARRIERS FOR THE POTENTIOMETRIC SENSING OF GUANIDINIUM IONS [J].
ASSUBAIE, FN ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1989, 114 (12) :1545-1550
[2]   SILVER-SELECTIVE MEMBRANE ELECTRODES USING ACYCLIC DITHIA BENZENE DERIVATIVE NEUTRAL CARRIERS - COMPARISON WITH RELATED MACROCYCLIC-COMPOUNDS [J].
CASABO, J ;
FLOR, T ;
ROMERO, MI ;
TEIXIDOR, F ;
PEREZJIMENEZ, C .
ANALYTICA CHIMICA ACTA, 1994, 294 (02) :207-213
[3]  
CHODHURY A, 1994, CHEM LETT, P489
[4]  
CHUNG S, IN PRESS TALANTA
[5]   COATED-WIRE ELECTRODES CONTAINING POLYMER IMMOBILIZED IONOPHORES BLENDED WITH POLY(VINYL CHLORIDE) [J].
CROSS, GG ;
FYLES, TM ;
SURESH, VV .
TALANTA, 1994, 41 (09) :1589-1595
[6]  
LEE SS, 1995, CHEM LETT, P109
[7]  
Moody G. J., 1971, SELECTIVE ION SENSIT
[8]   A LIPOPHILIC DERIVATIVE OF VITAMIN-B12 AS A SELECTIVE CARRIER FOR ANIONS [J].
SCHULTHESS, P ;
AMMANN, D ;
SIMON, W ;
CADERAS, C ;
STEPANEK, R ;
KRAUTLER, B .
HELVETICA CHIMICA ACTA, 1984, 67 (04) :1026-1032
[9]   MOLECULES WITH LARGE CAVITIES IN SUPRAMOLECULAR CHEMISTRY [J].
SEEL, C ;
VOGTLE, F .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1992, 31 (05) :528-549
[10]   LEAD(II) ION-SELECTIVE ELECTRODES BASED ON CROWN ETHERS [J].
SHEEN, SR ;
SHIH, JS .
ANALYST, 1992, 117 (11) :1691-1695