Liquid Chromatographic Method with Ultraviolet Absorbance Detection for Measurement of Rimonabant in Human Plasma

被引:0
|
作者
Chiadmi, Fouad [2 ]
Schlatter, Joel [1 ]
Chariot, Patrick [2 ,3 ,4 ]
机构
[1] Univ Hosp Jean Verdier, AP HP, Dept Pharm & Toxicol, F-93140 Bondy, France
[2] Hosp Jean Verdier, Dept Forens Med, Bondy, France
[3] Inst Rech Interdisciplinaires Enjeux Sociaux, Bobigny, France
[4] Univ Paris 13, UFR SMBH, Bobigny, France
关键词
Human plasma; liquid chromatography; UV detection; RECEPTOR ANTAGONIST; SR141716A; POTENT; RIO;
D O I
10.1080/00032710902807805
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rimonabant is a selective cannabinoid CB1 receptor antagonist licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma using high-performance liquid chromatography coupled to an ultraviolet (UV) detector. Rimonabant and loxapine (internal standard) were extracted from 500L of plasma. Chromatography was performed on a 250mm4.6mm C18 column using a mobile phase constituted of 0.05M ammonium acetate/methanol (25:75, v/v) at a flow rate of 1ml/min followed by UV detection at 250nm. Calibration curves covered a range from 13 (lower limit of quantification) to 1000.0ng/mL. Validation results demonstrated that rimonabant could be accurately and precisely quantified in human plasma. Limit of quantification was 13ng/mL. This simple method can be used for measuring rimonabant concentrations in human plasma in clinical practice.
引用
收藏
页码:833 / 841
页数:9
相关论文
共 50 条
  • [21] Simultaneous determination of ketamine and xylazine in canine plasma by liquid chromatography with ultraviolet absorbance detection
    Niedorf, F
    Bohr, HH
    Kietzmann, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2): : 421 - 426
  • [22] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD USING ULTRAVIOLET DETECTION FOR MEASURING METRIFONATE AND DICHLORVOS LEVELS IN HUMAN PLASMA
    UNNI, LK
    HANNANT, ME
    BECKER, RE
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 99 - 103
  • [23] Determination of laquinimod in plasma by coupled-column liquid chromatography with ultraviolet absorbance detection
    Edman, K
    Eriksson, B
    Svensson, L
    Gunnarsson, PL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02): : 311 - 316
  • [24] A high performance liquid chromatographic method for the measurement of total carnitine in human plasma and urine
    McEntyre, CJ
    Lever, M
    Storer, MK
    CLINICA CHIMICA ACTA, 2004, 344 (1-2) : 123 - 130
  • [25] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF LABETALOL IN PLASMA USING ULTRAVIOLET DETECTION
    HIDALGO, IJ
    MUIR, KT
    JOURNAL OF CHROMATOGRAPHY, 1984, 305 (01): : 222 - 227
  • [26] Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection
    Nielsen, SE
    Dragsted, LO
    JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02): : 379 - 386
  • [27] Simple high-performance liquid chromatographic assay for the determination of ciprofloxacin in human plasma with ultraviolet detection
    Maya, MT
    Gonçalves, NJ
    Silva, NB
    Morais, JA
    JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 305 - 309
  • [28] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF ATENOLOL FROM HUMAN PLASMA AND URINE - SIMULTANEOUS FLUORESCENCE AND ULTRAVIOLET DETECTION
    CHATTERJEE, DJ
    HURST, AK
    KODA, RT
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (04): : 791 - 806
  • [29] High-performance liquid chromatographic method for the determination of pioglitazone in human plasma using ultraviolet detection and its application to a pharmacokinetic study
    Sripalakit, Pattana
    Neamhom, Penporn
    Saraphanchotiwitthaya, Aurasorn
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 843 (02): : 164 - 169
  • [30] Simple and sensitive liquid chromatographic method with fluorimetric detection for the analysis of gabapentin in human plasma
    Chung, Tang-Chia
    Tai, Chih-Ta
    Wu, Hsin-Lung
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1119 (1-2) : 294 - 298