Using gold nanostars modified pencil graphite electrode as a novel substrate for design a sensitive and selective Dopamine aptasensor

被引:28
|
作者
Talemi, Rasoul Pourtaghavi [1 ]
Mousavi, Seyed Mehdi [1 ]
Afruzi, Hossein [2 ]
机构
[1] Kharazmi Univ, Fac Chem, Tehran, Iran
[2] Lorestan Univ, Fac Sci, Dept Chem, Lorestan, Iran
关键词
Dopamine; Aptasensor; Gold nanostars; Pencil graphite electrode; Electrochemical impedance spectroscopy; Biomedical application; ELECTROCHEMICAL BIOSENSOR; IMPEDIMETRIC APTASENSOR; DNA BIOSENSOR; STRAND DNA; NANOPARTICLES; SURFACE; NEUROTRANSMITTERS; HYBRIDIZATION;
D O I
10.1016/j.msec.2016.12.119
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
For the first time, gold nanostars (GNS) were applied for electrostatic and covalent immobilizing a thiol modified Dopamine aptamer on the pencil graphite electrode and signal amplification. Dopamine aptamer was immobilized on the gold nanostars through electrostatic interaction between negatively charged phosphate groups of aptamer and positively charged gold nanostars and Au-S well known covalent interaction. In the presence of Dopamine in the test solution, the charge transfer resistance (R-CT) on the electrode surface increased with the increase of the Dopamine concentration due to specific interaction between Dopamine aptamer and Dopamine molecules, which made a barrier for electrons and inhibited the electron-transfer. So, the proposed approach showed a high sensitivity and a wide linearity to Dopamine in the range from 1.0 (+/- 0.1) to 100.0 (+/- 0.3) ng L-1 (ppt) with detection and quantification limits of 0.29 (+/- 0.10) and 0.90 (+/- 0.08) ng L-1 (ppt), respectively. Finally, the sensor was successfully used for determination of Dopamine in biological (human blood plasma and urine) samples. The results open up the path for manufacturing cost effective aptasensors for other biomedical applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:700 / 708
页数:9
相关论文
共 50 条
  • [1] A Sensitive and Selective Electrochemical Investigation of Dopamine at Fabricated Sorbitol Film Modified Pencil Graphite Electrode: A Voltammetric Study
    Deepa, S.
    Swamy, B. E. Kumara
    Pai, K. Vasantakumar
    Mahanthesha, K. R.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (09): : 1240 - 1254
  • [2] An electrochemical label-free and sensitive thrombin aptasensor based on graphene oxide modified pencil graphite electrode
    Ahour, F.
    Ahsani, M. K.
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 764 - 769
  • [3] Determination of Epinephrine using a Novel Sensitive Electrochemiluminescence Sensor based on ZnO Nanoparticles Modified Pencil Graphite Electrode
    Zheng, Ruijuan
    Zhao, Chenhao
    Zhong, Jianhai
    Qiu, Zehai
    Hu, Zhibiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 9380 - 9390
  • [4] An electrochemical dopamine aptasensor using the modified Au electrode with spindle-shaped gold nanostructure
    Taheri, Ramezan Ali
    Eskandari, Khadijeh
    Negandary, Masoud
    MICROCHEMICAL JOURNAL, 2018, 143 : 243 - 251
  • [5] Sensitive and selective determination of vanillin in the presence of dopamine and uric acid using low-cost and trouble-free pencil graphite electrode modified with methyl orange
    Pradeepa, E.
    Nayaka, Y. Arthoba
    Manjushree, N. R.
    MATERIALS CHEMISTRY AND PHYSICS, 2023, 296
  • [6] Sensitive Adsorptive Voltammetric Method for Determination of Bisphenol A by Gold Nanoparticle/Polyvinylpyrrolidone-Modified Pencil Graphite Electrode
    Yaman, Yesim Tugce
    Abaci, Serdar
    SENSORS, 2016, 16 (06)
  • [7] Novel electrochemical sensing of galactose using GalOxNPs/CHIT modified pencil graphite electrode
    Sharma, Mamta
    Yadav, Pooja
    Sharma, Minakshi
    CARBOHYDRATE RESEARCH, 2019, 483
  • [8] Electrochemical Determination of Dopamine in Synthetic Urine Using an Adenine (AD) Modified Pencil Graphite Electrode (PGE)
    Korkmaz, Seyma
    Mulazimoglu, Ibrahim Ender
    Mulazimoglu, Aysen Demir
    ANALYTICAL LETTERS, 2024,
  • [9] Simple and sensitive detection of 4-nitrophenol in real water samples using gold nanoparticles modified pretreated graphite pencil electrode
    Rana, Azeem
    Kawde, Abdel-Nasser
    Ibrahim, Mohamed
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 820 : 24 - 31
  • [10] Determination of atropine sulfate using a novel sensitive DNA-biosensor based on its interaction on a modified pencil graphite electrode
    Ensafi, Ali A.
    Nasr-Esfahani, Parisa
    Heydari-Bafrooei, Esmaeil
    Rezaei, B.
    TALANTA, 2015, 131 : 149 - 155