Analysis of Polygonal Distance Protection Relay of Transmission Line Affected by SMES Device

被引:0
|
作者
Yang, Jun [1 ]
Zhang, Wenjia [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Jiangsu Elect Power Co, Econ Res Inst, Nanjing 210008, Jiangsu, Peoples R China
来源
PROCEEDINGS OF THE 26TH INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS 2013) | 2014年 / 58卷
关键词
Superconducting Magnetic Energy Storage; Distance relay; PSCAD simulation; Tripping Characteristic;
D O I
10.1016/j.phpro.2014.09.049
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Because of unique advantages in rapid response and independent control of active and reactive power, Superconducting Magnetic Energy Storage (SMES) device will be widely used in the power system. The SMES exchanges power with power grid in the charging and discharging process, so it may affect the performance of protection relay of transmission line, which will lead to mal-operation. Based on SMES model, the tripping characteristic of polygonal distance relay for single-machine-infinite-bus performance of polygonal distance relay with SMES. The simulation results show the measured impedance of polygonal distance relay is changed by SMES, and polygonal distance relay will make mal-operation when faults occur in the boundary of protection zone. Also an improving distance relay is proposed to solve the problem. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:272 / 276
页数:5
相关论文
共 50 条
  • [41] Impedance correction method of distance relay on high voltage transmission line
    Seghir, Samira
    Bouthiba, Tahar
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (01): : 18 - 23
  • [42] Impact Analyses of Wind Farm on Performances of Transmission Line Relay Protection
    Jin WANG Baohui ZHANG School of Electrical EngineeringXian Jiaotong UniversityXian China
    电力系统自动化, 2012, 36 (08) : 148 - 153
  • [43] Impact analyses of wind farm on performances of transmission line relay protection
    Wang, Jin
    Zhang, Baohui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (08): : 148 - 153
  • [44] Digital relay software reliability allocation optimisation for transmission line protection
    Roy, Diptendu Sihna
    Panda, A.K.
    Mohanta, Dusmanta Kumar
    International Journal of Reliability and Safety, 2009, 3 (04): : 413 - 426
  • [45] Protection of TCSC Transmission Line by Wavelet Based Advance Mho Relay
    Manori, Ashok
    Tripathy, Manoj
    2018 5TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (UPCON), 2018, : 106 - 109
  • [46] ALGORITHMS FOR DISTANCE RELAY PROTECTION FROM INTERPHASE FAULTS ON TRANSMISSION-LINES
    GELFAND, YS
    ZISMAN, LS
    ELECTRICAL TECHNOLOGY, 1975, (03): : 91 - 105
  • [47] Microcontroller-based numerical quadrilateral relay for the transmission line protection
    Shrivastava, Kiran
    Vishwakarma, D. N.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2007, 35 (12) : 1301 - 1315
  • [48] Research on the Protection Range of Distance Protection Zone I for Short Transmission Line
    Zhao Zhihong
    Zhao Yue
    Cheng Lei
    Wang Bin
    Huang Zhihua
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1094 - 1098
  • [49] Study on a novel method of distance protection in transmission line with STATCOM
    Liu Qing
    Wang Zeng-ping
    Zhang Yuan
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [50] Recommendations for main stages setting-up of line distance relay protection
    Minh, Tran Hoang Quang
    International Journal of Future Generation Communication and Networking, 2015, 8 (05): : 147 - 156