Analysis of Polygonal Distance Protection Relay of Transmission Line Affected by SMES Device

被引:0
|
作者
Yang, Jun [1 ]
Zhang, Wenjia [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Jiangsu Elect Power Co, Econ Res Inst, Nanjing 210008, Jiangsu, Peoples R China
来源
PROCEEDINGS OF THE 26TH INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS 2013) | 2014年 / 58卷
关键词
Superconducting Magnetic Energy Storage; Distance relay; PSCAD simulation; Tripping Characteristic;
D O I
10.1016/j.phpro.2014.09.049
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Because of unique advantages in rapid response and independent control of active and reactive power, Superconducting Magnetic Energy Storage (SMES) device will be widely used in the power system. The SMES exchanges power with power grid in the charging and discharging process, so it may affect the performance of protection relay of transmission line, which will lead to mal-operation. Based on SMES model, the tripping characteristic of polygonal distance relay for single-machine-infinite-bus performance of polygonal distance relay with SMES. The simulation results show the measured impedance of polygonal distance relay is changed by SMES, and polygonal distance relay will make mal-operation when faults occur in the boundary of protection zone. Also an improving distance relay is proposed to solve the problem. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:272 / 276
页数:5
相关论文
共 50 条
  • [1] Development of nonuniform transmission line protection for accurate distance protection: Computational analysis of an adaptive distance relay characteristic
    Tavalaei, Jalal
    Habibuddin, Mohd Hafiz
    Naderipour, Amirreza
    Zin, Abdullah Asuhaimi Mohd
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2018, 28 (04):
  • [2] A new approach of Mho distance relay for Transmission line protection
    Ahmed, Abdullah Hamed
    Sultan, Ahmed Jasim
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENGINEERING TECHNIQUES (ICSET 2019), 2019, 518
  • [3] An Efficient Method of Automatic Distance Relay Settings for Transmission Line Protection
    Penthong, Thanakorn
    Hongesombut, Komsan
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [4] A distance protection relay for a 1000-kV UHV transmission line
    Xu, Z. Y.
    Huang, S. F.
    Ran, Li
    Liu, J. F.
    Qin, Y. L.
    Yang, Q. X.
    He, J. L.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1795 - 1804
  • [5] Design of virtual distance protection for offline transmission line relay testing
    Celeita, David
    Flores, Andres
    Ramos, Gustavo
    Pohl, Mauricio
    2018 IEEE 38TH CENTRAL AMERICA AND PANAMA CONVENTION (CONCAPAN XXXVIII), 2018, : 309 - 314
  • [6] Zone Protection System of Transmission Line by Distance Relay using Matlab/Simulink
    Ferdous, Farhana
    Ruma
    2018 INTERNATIONAL CONFERENCE ON ADVANCEMENT IN ELECTRICAL AND ELECTRONIC ENGINEERING (ICAEEE), 2018,
  • [7] Modelling and simulation of the impact of SVC on existing distance relay for transmission line protection
    Behera, Sabyasachi
    Raja, P.
    Moorthi, S.
    2015 INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2015, : 151 - 156
  • [8] New distance relay compensation algorithm for double-circuit transmission line protection
    Seyedi, H.
    Behroozi, L.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (10) : 1011 - 1018
  • [9] Using a Combined Artificial Intelligent Approach In Distance Relay For Transmission Line Protection In EPS
    Kamel, T. S.
    Hassan, M. A. Moustafa
    El-Morshedy, A.
    2009 FIFTH INTERNATIONAL CONFERENCE ON SOFT COMPUTING, COMPUTING WITH WORDS AND PERCEPTIONS IN SYSTEM ANALYSIS, DECISION AND CONTROL, 2010, : 192 - 197
  • [10] Development of Three Zone Quadrilateral Adaptive Distance Relay for the Protection of Parallel Transmission line
    Srivani, S. G.
    Panduranga, Vittal K.
    Atla, Chandrasekhar Reddy
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 324 - 329