Re-trapping and cooling of highly-charged ions

被引:1
作者
Hobein, M. [1 ]
Solders, A. [1 ]
Suhonen, M. [1 ]
Liu, Y. [1 ]
Kamalou, O. [1 ]
Schuch, R. [1 ]
机构
[1] Stockholm Univ, S-10691 Stockholm, Sweden
来源
14TH INTERNATIONAL CONFERENCE ON THE PHYSICS OF HIGHLY CHARGED IONS (HCI 2008) | 2009年 / 163卷
关键词
PRECISION MASS MEASUREMENTS; PENNING TRAP;
D O I
10.1088/1742-6596/163/1/012109
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Presently, a trapping system for cooling highly-charged ions (HCI) is being set up at AlbaNova at Stockholm University. The experiment aims at production of low temperature (emittance) HCI at very low energy. HCI are extracted from the new Stockholm EBIT (S-EBIT) before evaporative cooling is applied in a Penning trap. In the future the cooled ions will be injected into the precision trap of the high-precision mass spectrometer SMILETRAP H. In first tests the emittance of trapped ions was measured and it was shown that highly and low-charged ions could be simultaneously stored.
引用
收藏
页数:4
相关论文
共 31 条
[11]   Status of deceleration and laser spectroscopy of highly charged ions at HITRAP [J].
Andelkovic, Zoran ;
Birkl, Gerhard ;
Fedotova, Svetlana ;
Hannen, Volker ;
Herfurth, Frank ;
Koenig, Kristian ;
Kotovskiy, Nikita ;
Maass, Bernhard ;
Vollbrecht, Jonas ;
Murboeck, Tobias ;
Neidherr, Dennis ;
Noertershaeuser, Wilfried ;
Schmidt, Stefan ;
Vogel, Manuel ;
Vorobjev, Gleb ;
Weinheimer, Christian .
HYPERFINE INTERACTIONS, 2015, 235 (1-3) :37-44
[12]   Pulsed gas injection for X-ray spectroscopy of highly charged ions stored in the magnetic trapping mode of an electron beam ion trap [J].
Schweikhard, L ;
Beiersdorfer, P ;
Brown, GV ;
Lopez-Urrutia, JRC ;
Utter, SB ;
Widmann, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 142 (03) :245-252
[13]   Perspectives on testing fundamental physics with highly charged ions in Penning traps [J].
Blaum, K. ;
Eliseev, S. ;
Sturm, S. .
QUANTUM SCIENCE AND TECHNOLOGY, 2021, 6 (01)
[14]   Precision measurements with highly charged ions at rest: The HITRAP project at GSI [J].
Herfurth, F ;
Beier, T ;
Dahl, L ;
Eliseev, S ;
Heinz, S ;
Kester, O ;
Kozhuharov, C ;
Maero, G ;
Quint, W .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 251 (2-3) :266-272
[15]   Vacuum requirements for Penning trap mass spectrometry with highly charged ions [J].
Leistenschneider, Erich ;
Kwiatkowski, A. A. ;
Dilling, J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 (463) :496-498
[16]   Precision laser spectroscopy without optical detectionForbidden transitions in highly charged ions [J].
Manuel Vogel ;
Wolfgang Quint .
Hyperfine Interactions, 2010, 196 :93-105
[17]   High-intensity laser experiments with highly charged ions in a Penning trap [J].
Ringleb, S. ;
Kiffer, M. ;
Stallkamp, N. ;
Kumar, s ;
Hofbrucker, J. ;
Reich, B. ;
Arndt, B. ;
Brenner, G. ;
Ruiz-Lopez, M. ;
Duester, S. ;
Vogel, M. ;
Tiedtke, K. ;
Quint, W. ;
Stoehlker, Th ;
Paulus, G. G. .
PHYSICA SCRIPTA, 2022, 97 (08)
[18]   Towards high precision in-trap laser spectroscopy of highly charged ions [J].
Andjelkovic, Zoran ;
Bharadia, Shailen ;
Sommer, Bettina ;
Vogel, Manuel ;
Noertershaeuser, Wilfried .
LASER 2009: RECENT ACHIEVEMENTS AND FUTURE PROSPECTS, 2010, :81-91
[19]   Stopping highly charged ions in a laser-cooled one component plasma of 24Mg+ ions [J].
Bussmann, M ;
Schramm, U ;
Habs, D ;
Kolhinen, VS ;
Szerypo, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 251 (2-3) :179-189
[20]   SMILETRAP -: A Penning trap facility for precision mass measurements using highly charged ions [J].
Bergström, I ;
Carlberg, C ;
Fritioff, T ;
Douysset, G ;
Schönfelder, J ;
Schuch, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (03) :618-651