An audit of radiotherapy patient doses measured with in vivo semiconductor detectors

被引:16
作者
Adeyemi, A [1 ]
Lord, J [1 ]
机构
[1] ROYAL BERKSHIRE & BATTLE HOSP NHS TRUST,DEPT MED PHYS,READING RG1 5AN,BERKS,ENGLAND
关键词
D O I
10.1259/bjr.70.832.9166077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Uncertainties exist both in the basic data from which a radiotherapy plan is produced and in the process whereby such a plan is translated into the patient set-up during treatment. Individual parts of the radiotherapy process are subject to checks, but the overall accuracy of treatment delivery is not routinely evaluated. In vivo dosimetry by means of a semiconductor detector system can be used to measure the cumulative error in the radiotherapy treatment dose delivered. A direct patient dosimetry system was commissioned and introduced in January 1993 for the routine evaluation of the doses patients receive. Since its introduction a total of 1000 patients have been monitored for a range of radiotherapy applications, comprising 300 breast treatments (6 MV X-rays), 150 head and neck treatments (6 MV X-rays) and 550 pelvis, abdomen and thorax treatments (10 MV X-rays). The results of this audit show that less than 5% of all patients monitored gave a systematic error more than +/-5% for a single field, or more than +/-2.5% for the ''estimated overall error'' in the isocentre dose. The causes of these errors were identified and appropriate action taken where necessary. It is suggested that this method could be used routinely in radiotherapy treatment to assess the overall performance of the treatment process.
引用
收藏
页码:399 / 408
页数:10
相关论文
共 10 条
  • [1] EVALUATION OF TEMPERATURE EFFECTS IN P-TYPE SILICON DETECTORS
    GRUSELL, E
    RIKNER, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (05) : 527 - 534
  • [2] *I PHYS SCI MED, 1990, PHYS MED BIOL, V35, P1355
  • [3] *INT COMM RAD UN M, 1976, 24 INT COMM RAD UN M
  • [4] PATIENT DOSIMETRY QUALITY ASSURANCE PROGRAM WITH A COMMERCIAL DIODE SYSTEM
    LEE, PC
    SAWICKA, JM
    GLASGOW, GP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05): : 1175 - 1182
  • [5] QUALITY ASSURANCE IN RADIOTHERAPY BY INVIVO DOSIMETRY .1. ENTRANCE DOSE MEASUREMENTS, A RELIABLE PROCEDURE
    LEUNENS, G
    VANDAM, J
    DUTREIX, A
    VANDERSCHUEREN, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1990, 17 (02) : 141 - 151
  • [6] QUALITY ASSURANCE IN RADIOTHERAPY BY INVIVO DOSIMETRY .2. DETERMINATION OF THE TARGET ABSORBED DOSE
    LEUNENS, G
    VANDAM, J
    DUTREIX, A
    VANDERSCHUEREN, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1990, 19 (01) : 73 - 87
  • [7] CHARACTERISTICS OF SILICON DIODES AS PATIENT DOSIMETERS IN EXTERNAL RADIATION-THERAPY
    NILSSON, B
    RUDEN, BI
    SORCINI, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (03) : 279 - 288
  • [8] DETECTION OF ERRORS IN INDIVIDUAL PATIENTS IN RADIOTHERAPY BY SYSTEMATIC IN-VIVO DOSIMETRY
    NOEL, A
    ALETTI, P
    BEY, P
    MALISSARD, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 1995, 34 (02) : 144 - 151
  • [9] GENERAL SPECIFICATIONS FOR SILICON SEMICONDUCTORS FOR USE IN RADIATION-DOSIMETRY
    RIKNER, G
    GRUSELL, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) : 1109 - 1117
  • [10] World Health Organisation (WHO), 1988, QUAL ASS RAD