Bromate determination in water after membrane complexation and total reflection X-ray fluorescence analysis

被引:36
作者
Hatzistavros, Vasilios S. [1 ]
Koulouridakis, Pavlos E. [1 ]
Aretaki, Ioanna I. [1 ]
Kallithrakas-Kontos, Nikolaos G. [1 ]
机构
[1] Tech Univ Crete, Analyt Environm Chem Lab, GR-73100 Khania, Greece
关键词
D O I
10.1021/ac061231c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for the determination of trace levels of bromates by selective membrane collection is presented. Various membranes containing a few micrograms of different complexing reagents in a poly(vinyl chloride) matrix were tested. These membranes were produced on the surface of quartz glass (reflectors), and they were immersed in solutions containing bromate and bromide ions. At the first stage the prepared membranes collected both bromate and bromide ions, so different bromide masking agents were put in the analyzed solutions to avoid bromide collection. By the end of the equilibration time, the reflectors were left to dry, and they were analyzed by total reflection X-ray fluorescence (TXRF). The poly(vinyl chloride) with aliquat-336 membrane and o-dianisidin complexing agent gave the best results. The minimum detection limit was equal to 0.9 ng/mL for ultrapure water and 1.0 ng/mL for drinking water.
引用
收藏
页码:2827 / 2832
页数:6
相关论文
共 27 条
[11]  
Jenkins R., 1988, CHEM ANAL SERIES MON, V99
[12]   TRACE-LEVEL DETERMINATION OF BROMATE IN OZONATED DRINKING-WATER USING ION CHROMATOGRAPHY [J].
JOYCE, RJ ;
DHILLON, HS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :165-171
[13]   Selective mercury determination after membrane complexation and total reflection X-ray fluorescence analysis [J].
Koulouridakis, PE ;
Kallithrakas-Kontos, NG .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4315-4319
[14]   Recovery of Cr(VI) by quaternary ammonium compounds [J].
Lo, SL ;
Shiue, SF .
WATER RESEARCH, 1998, 32 (01) :174-178
[15]   Evaluation of different electrolyte systems and on-line preconcentrations for the analysis of haloacetic acids by capillary zone electrophoresis [J].
Martínez, D ;
Borrull, F ;
Calull, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :187-196
[16]   An electrochemical enrichment procedure for the determination of heavy metals by total-reflection X-ray fluorescence spectroscopy [J].
Ritschel, A ;
Wobrauschek, P ;
Chinea, E ;
Grass, F ;
Fabjan, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (10) :1449-1454
[17]  
Rosenblatt D.H., 1972, PROGR INORGANIC CHEM, P15
[18]   Preconcentration and separation of haloacetic acids by ion chromatography [J].
Sarzanini, C ;
Bruzzoniti, MC ;
Mentasti, E .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :197-211
[19]   Coupled-diffusion transport of Cr(VI) across anion-exchange membranes prepared by physical and chemical immobilization methods [J].
Scindia, YM ;
Pandey, AK ;
Reddy, AVR .
JOURNAL OF MEMBRANE SCIENCE, 2005, 249 (1-2) :143-152
[20]   Use of self-plasticizing EVA membrane for potentiometric anion detection [J].
Torres, KYC ;
Garcia, CAB ;
Fernandes, JCB ;
Neto, GD ;
Kuboto, LT .
TALANTA, 2001, 53 (04) :807-814