Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates

被引:275
作者
Gervais, Luc [1 ,2 ]
Delamarche, Emmanuel [1 ]
机构
[1] IBM Res GmbH, Zurich Res Lab, CH-8803 Ruschlikon, Switzerland
[2] Univ Basel Hosp, CH-4031 Basel, Switzerland
关键词
C-REACTIVE PROTEIN; ACUTE MYOCARDIAL-INFARCTION; HEART-FAILURE; IMMUNOASSAYS; SYSTEMS; BIOMARKERS; CHIPS; PERFORMANCE; PLATFORM; DEVICES;
D O I
10.1039/b906523g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Point-of-care diagnostics will strongly benefit from miniaturization based on microfluidics because microfluidics integrate functions that can together preserve valuable samples and reagents, increase sensitivity of a test, and accelerate mass transport limited reactions. But a main challenge is to incorporate reagents into microfluidics and to make microfluidics simple to use. Here, we integrate microfluidic functional elements, some of which were developed earlier, and reagents such as detection antibodies (dAbs), capture antibodies (cAbs) and analyte molecules for making one-step immunoassays: the integrated device only requires the addition of sample to trigger a cascade of events powered by capillary forces for effecting a sandwich immunoassay that is read using a fluorescence microscope. The microfluidic elements comprise a sample collector, delay valves, flow resistors, a deposition zone for dAbs, a reaction chamber sealed with a polydimethylsiloxane (PDMS) substrate, and a capillary pump and vents. Parameters for depositing 3.6 nL of a solution of dAb on the chip using an inkjet are optimized and the PDMS substrate is patterned with analytes, which provide a positive control, and cAbs. Various storage conditions of the patterned PDMS are investigated for up to 6 months revealing that storage with a desiccant preserved at least 51% of the activity of the cAbs. C-reactive protein (CRP), a general inflammation and cardiac marker, is detected using this one-step chip using only 5 mu L of human serum by measuring fluorescent signals from 30 x 100 mm(2) areas of the PDMS substrate in the wet reaction chamber. The one-step chip can detect CRP at a concentration of 10 ng mL(-1) in less than 3 min and below 1 ng mL(-1) within 14 min. The work presented here may spur the adoption of fluorescence immunoassays using capillary driven microfluidics and PDMS substrates for point-of-care diagnostics.
引用
收藏
页码:3330 / 3337
页数:8
相关论文
共 33 条
[11]   Mining the plasma proteome for cancer biomarkers [J].
Hanash, Samir M. ;
Pitteri, Sharon J. ;
Faca, Vitor M. .
NATURE, 2008, 452 (7187) :571-579
[12]   Power-free sequential injection for microchip immunoassay toward point-of-care testing [J].
Hosokawa, K ;
Omata, M ;
Sato, K ;
Maeda, M .
LAB ON A CHIP, 2006, 6 (02) :236-241
[13]  
*INV MED INN INC, CLEARBL PREGN TESTS
[14]   Silane-dextran chemistry on lateral flow polymer chips for immunoassays [J].
Joensson, Christina ;
Aronsson, Magnus ;
Rundstroem, Gerd ;
Pettersson, Christer ;
Mendel-Hartvig, Ib ;
Bakker, Jimmy ;
Martinsson, Erik ;
Liedberg, Bo ;
MacCraith, Brian ;
Oehman, Ove ;
Melin, Jonas .
LAB ON A CHIP, 2008, 8 (07) :1191-1197
[15]   Autonomous microfluidic capillary system [J].
Juncker, D ;
Schmid, H ;
Drechsler, U ;
Wolf, H ;
Wolf, M ;
Michel, B ;
de Rooij, N ;
Delamarche, E .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6139-6144
[16]  
KHOSRAVI MJ, 1990, CLIN CHEM, V36, P169
[17]   A timer-actuated immunoassay cassette for detecting molecular markers in oral fluids [J].
Liu, Changchun ;
Qiu, Xianbo ;
Ongagna, Serge ;
Chen, Dafeng ;
Chen, Zongyuan ;
Abrams, William R. ;
Malamud, Daniel ;
Corstjens, Paul L. A. M. ;
Bau, Haim H. .
LAB ON A CHIP, 2009, 9 (06) :768-776
[18]   Patterned paper as a platform for inexpensive, low-volume, portable bioassays [J].
Martinez, Andres W. ;
Phillips, Scott T. ;
Butte, Manish J. ;
Whitesides, George M. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (08) :1318-1320
[19]   Atomic force microscopy study of the interaction between adsorbed poly(ethylene oxide) layers: Effects of surface modification and approach velocity [J].
McLean, SC ;
Lioe, H ;
Meagher, L ;
Craig, VSJ ;
Gee, ML .
LANGMUIR, 2005, 21 (06) :2199-2208
[20]   An integrated microfluidic platform for sensitive and rapid detection of biological toxins [J].
Meagher, Robert J. ;
Hatch, Anson V. ;
Renzi, Ronald F. ;
Singh, Anup K. .
LAB ON A CHIP, 2008, 8 (12) :2046-2053