Non-invasive blood glucose monitoring by means of near infrared spectroscopy: Methods for improving the reliability of the calibration models

被引:54
作者
Muller, UA [1 ]
Mertes, B [1 ]
Fischbacher, C [1 ]
Jageman, KU [1 ]
Danzer, K [1 ]
机构
[1] UNIV JENA, INST ANORGAN & ANALYT CHEM, D-6900 JENA, GERMANY
关键词
glucose self monitoring; type-1-diabetes; NIR-spectroscopy; non-invasive blood glucose determination; multivariate calibration;
D O I
10.1177/039139889702000509
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The feasibility of using near infrared reflection spectroscopy for non-invasive blood glucose monitoring is discussed. Spectra were obtained using a diode-array spectrometer with a fiberoptic measuring head with a wavelength ranging from 800 nm to 1350 nm. Calibration was performed using partial least-squares regression and radial basis function networks. The results of different methods used to evaluate the quality of the recorded spectra in order to improve the reliability of the calibration models, are presented.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 29 条
[11]  
HEINEMANN L, 1993, PHARM PHARM VERSCHIE
[12]   APPLICATION OF NEAR-INFRARED SPECTROSCOPY FOR NONINVASIVE DETERMINATION OF BLOOD-TISSUE GLUCOSE USING NEURAL NETWORKS [J].
JAGEMANN, KU ;
FISCHBACHER, C ;
MULLER, UA ;
MERTES, B .
ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 1995, 191 :179-190
[13]  
JANSSON PA, 1988, AM J PHYSIOL, V88, pE118
[14]   NONINVASIVE MEASUREMENT OF BLOOD-GLUCOSE CONCENTRATIONS BY ANALYZING FOURIER-TRANSFORM INFRARED ABSORBENCY SPECTRA THROUGH ORAL-MUCOSA [J].
KAJIWARA, K ;
UEMURA, T ;
KISHIKAWA, H ;
NISHIDA, K ;
HASHIGUCHI, Y ;
UEHARA, M ;
SAKAKIDA, M ;
ICHINOSE, K ;
SHICHIRI, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 :S17-S22
[15]   NEW NONINVASIVE TRANSCUTANEOUS APPROACH TO BLOOD-GLUCOSE MONITORING - SUCCESSFUL GLUCOSE MONITORING ON HUMAN 75-G OGTT WITH NOVEL SAMPLING CHAMBER [J].
KAYASHIMA, S ;
ARAI, T ;
KIKUCHI, M ;
SATO, N ;
NAGATA, N ;
TAKATANI, O ;
ITO, N ;
KIMURA, J ;
KURIYAMA, T ;
KANEYOSHI, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :752-757
[16]   NONINVASIVE BLOOD-GLUCOSE ASSAY BY NEAR-INFRARED DIFFUSE-REFLECTANCE SPECTROSCOPY OF THE HUMAN INNER LIP [J].
MARBACH, R ;
KOSCHINSKY, T ;
GRIES, FA ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (07) :875-881
[17]  
MARBACH R, 1993, 8 VDI
[18]   ON LINE CONTINUOUS MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE IN MEN BY COMBINING PORTABLE GLUCOSENSOR WITH MICRODIALYSIS [J].
MEYERHOFF, C ;
BISCHOF, F ;
STERNBERG, F ;
ZIER, H ;
PFEIFFER, EF .
DIABETOLOGIA, 1992, 35 (11) :1087-1092
[19]   REGULARIZATION IN THE SELECTION OF RADIAL BASIS FUNCTION CENTERS [J].
ORR, MJL .
NEURAL COMPUTATION, 1995, 7 (03) :606-623
[20]   A GLUCOSE MONITORING-SYSTEM FOR ON LINE ESTIMATION IN MAN OF BLOOD-GLUCOSE CONCENTRATION USING A MINIATURIZED GLUCOSE SENSOR IMPLANTED IN THE SUBCUTANEOUS TISSUE AND A WEARABLE CONTROL UNIT [J].
POITOUT, V ;
MOATTISIRAT, D ;
REACH, G ;
ZHANG, Y ;
WILSON, GS ;
LEMONNIER, F ;
KLEIN, JC .
DIABETOLOGIA, 1993, 36 (07) :658-663