Concrete Cracking Control of Chamber wall in Jiepai Ship-lock Project

被引:2
作者
Sheng, Z. B. [1 ,2 ]
Deng, C. L. [2 ]
Xiong, J. B. [2 ]
机构
[1] Minist Commun, Key Lab Durabil Technol Harbor & Marine Struct, Guangzhou, Peoples R China
[2] CCCC Fourth Harbor Engn Inst Co Ltd, Guangzhou, Peoples R China
来源
2020 3RD INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT | 2020年 / 531卷
关键词
D O I
10.1088/1755-1315/531/1/012043
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on analysis of crack problem of chamber wall ship lock expansion project in Jiepai province, the related research of countermeasures have been made, to solve the cracks occurs in the structure. The countermeasure of cracks are analysed by monitoring internal-external temperature and shrinkage stress of chamber wall. It is provided that the rational measures could make less cracks occur, including fiber lattice with curing of insulation and moisture materials and optimization of proportion mix. A series of investigations are carried out insitu and prove countermeasures of cracking control effectively. This paper states the technical details and developing of inner temperature and shrinkage in chamber wall by adopting above measures.
引用
收藏
页数:5
相关论文
共 7 条
  • [1] Frosch RJ, 1999, ACI STRUCT J, V96, P437
  • [2] A PLASTIC-DAMAGE MODEL FOR CONCRETE
    LUBLINER, J
    OLIVER, J
    OLLER, S
    ONATE, E
    [J]. INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 1989, 25 (03) : 299 - 326
  • [3] Solikin M, 2013, PERTANIKA J SCI TECH, V21, P589
  • [4] Using the maturity method in concrete cracking control at early ages
    Waller, V
    d'Aloïa, L
    Cussigh, F
    Lecrux, S
    [J]. CEMENT & CONCRETE COMPOSITES, 2004, 26 (05) : 589 - 599
  • [5] Xia N., 2002, EXPT STUDY ANTICRACK
  • [6] Xiaolei L., 2010, INT C INF SCI ENG
  • [7] Zhongren F., 2009, THERMAL CRACKING CON