Oral platelet aggregation inhibitor Ro 48-3657: Determination of the active metabolite and its prodrug in plasma and urine by high-performance liquid chromatography using automated column switching

被引:10
作者
Timm, U
Zumbrunnen, R
Erdin, R
Singer, M
Steiner, B
机构
[1] Pharmaceutical Research Department, F. Hoffmann-La Roche Ltd.
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1997年 / 691卷 / 02期
关键词
column switching; platelet inhibitor; GP IIb-IIIa receptor; Ro; 48-3657;
D O I
10.1016/S0378-4347(96)00477-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 mu l of plasma) and 25 ng/ml (50 mu l of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.
引用
收藏
页码:397 / 407
页数:11
相关论文
共 9 条
  • [1] GOGGIN T, UNPUB CLIN PHARM THE
  • [2] BIOLOGICAL SAMPLE PREPARATION AND DATA REDUCTION CONCEPTS IN PHARMACEUTICAL ANALYSIS
    JOHNSON, EL
    REYNOLDS, DL
    WRIGHT, DS
    PACHLA, LA
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (08) : 372 - 379
  • [3] FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - A NEW CHROMATOGRAPH FOR PHARMACOKINETIC DRUG-MONITORING BY DIRECT INJECTION OF BODY-FLUIDS
    ROTH, W
    BESCHKE, K
    JAUCH, R
    ZIMMER, A
    KOSS, FW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1981, 222 (01): : 13 - 22
  • [4] Timm U., 1996, Laboratory Automation and Information Management, V32, P7, DOI 10.1016/1381-141X(96)00002-0
  • [5] A NEW APPROACH FOR DEALING WITH THE STABILITY OF DRUGS IN BIOLOGICAL-FLUIDS
    TIMM, U
    WALL, M
    DELL, D
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1985, 74 (09) : 972 - 977
  • [6] DETERMINATION OF A NEW NON-BENZODIAZEPINE ANXIOLYTIC AND ITS O-DEMETHYL METABOLITE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN-SWITCHING
    TIMM, U
    HOPFGARTNER, G
    ERDIN, R
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 456 (01): : 21 - 31
  • [7] TIMM U, 1990, DATA HANDL SCI TECHN, V6, P329, DOI 10.1016/S0922-3487(08)70179-5
  • [8] Orally active fibrinogen receptor antagonists .2. Amidoximes as prodrugs of amidines
    Weller, T
    Alig, L
    Beresini, M
    Blackburn, B
    Bunting, S
    Hadvary, P
    Muller, MH
    Knopp, D
    LevetTrafit, B
    Lipari, MT
    Modi, NB
    Muller, M
    Refino, CJ
    Schmitt, M
    Schonholzer, P
    Weiss, S
    Steiner, B
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 1996, 39 (16) : 3139 - 3147
  • [9] USE OF DIRECT INJECTION PRECOLUMN TECHNIQUES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE RETINOIDS ACITRETIN AND 13-CIS-ACITRETIN IN PLASMA
    WYSS, R
    BUCHELI, F
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2): : 55 - 62