Application of UV Light-Emitting Diodes to Adenovirus in Water

被引:63
作者
Oguma, Kumiko [1 ]
Rattanakul, Surapong [1 ]
Bolton, James R. [2 ]
机构
[1] Univ Tokyo, Res Ctr Adv Sci & Technol, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[2] Bolton Photosci Inc, 628 Cheriton Crescent NW, Edmonton, AB T6R 2M5, Canada
基金
日本科学技术振兴机构; 日本学术振兴会;
关键词
IODIDE-IODATE ACTINOMETERS; DISINFECTION; INACTIVATION; FERRIOXALATE; VALIDATION; SYSTEMS; VIRUSES; JAPAN; LAMPS; LEDS;
D O I
10.1061/(ASCE)EE.1943-7870.0001061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A ring-shaped disinfection apparatus has been developed containing twenty ultraviolet-light-emitting diodes (UV-LEDs) with emission at 285nm. The apparatus was applied to Escherichia coli, Q, MS2, and adenovirus in water. The reduction-equivalent fluence in the apparatus was determined, based on a modification of the protocol for the bench-scale challenge test by low-pressure (LP) UV lamp systems (LPUV). All species demonstrated log-linear inactivation profiles versus the fluence, and the inactivation rate constants for E. coli, Q, MS2, and adenovirus were 0.157, 0.037, 0.029, and 0.023cm2/mJ, respectively. The inactivation rate constant for adenovirus under the UV-LED exposure (kUV-LED) was higher than that under a LPUV lamp (kLPUV), and the ratio of kUV-LED to kLPUV, which is approximated as a germicidal factor at 285nm, was 1.15 for adenovirus. To conclude, this study demonstrated a high potential of the 285nm UV-LEDs to inactivate microorganisms in water. The germicidal factor found for adenovirus implies that the 285nm UV-LED could be a good option to inactivate adenovirus in water. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:6
相关论文
共 28 条
[21]   Spectral sensitivity of Bacillus subtilis spores and MS2 Coliphage for validation testing of ultraviolet reactors for water disinfection [J].
Mamane-Gravetz, H ;
Linden, KG ;
Cabaj, A ;
Sommer, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (20) :7845-7852
[22]   Application of UV light emitting diodes to batch and flow-through water disinfection systems [J].
Oguma, Kumiko ;
Kita, Ryo ;
Sakai, Hiroshi ;
Murakami, Michio ;
Takizawa, Satoshi .
DESALINATION, 2013, 328 :24-30
[23]  
Rattanakul S., 2014, Journal of Water and Environment Technology, V12, P511, DOI 10.2965/jwet.2014.511
[24]  
Seth P., 1999, ADENOVIRUSES BASIC B
[25]   Inactivation of norovirus by chlorine disinfection of water [J].
Shin, Gwy-Am ;
Sobsey, Mark D. .
WATER RESEARCH, 2008, 42 (17) :4562-4568
[26]   Enhanced effectiveness of medium-pressure ultraviolet lamps on human adenovirus 2 and its possible mechanism [J].
Shin, Gwy-Am ;
Lee, Jung-Keun ;
Linden, Karl G. .
WATER SCIENCE AND TECHNOLOGY, 2009, 60 (04) :851-857
[27]  
USEPA (U.S. Environmental Protection Agency), 2015, CCL 4 MICR IN PRESS
[28]   Application of GaN-based ultraviolet-C light emitting diodes - UV LEDs - for water disinfection [J].
Wuertele, M. A. ;
Kolbe, T. ;
Lipsz, M. ;
Kuelberg, A. ;
Weyers, M. ;
Kneissl, M. ;
Jekel, M. .
WATER RESEARCH, 2011, 45 (03) :1481-1489