SARS-CoV-2 viral load in heat and humidity exchange filters during invasive mechanical ventilation of patients with COVID-19

被引:1
作者
Fulceri, Giorgio Enzo [1 ,2 ]
Morecchiato, Fabio [3 ]
Antonelli, Alberto [3 ,4 ]
Bonizzoli, Manuela [1 ,2 ]
Cecchi, Michele [5 ]
Rossolini, Gian Maria [3 ,4 ]
Peris, Adriano [1 ,2 ]
机构
[1] Florence Careggi Univ Hosp, Intens Care Unit, Florence, Italy
[2] Florence Careggi Univ Hosp, Reg ECMO Referral Ctr, Florence, Italy
[3] Univ Florence, Dept Expt & Clin Med, Florence, Italy
[4] Florence Careggi Univ Hosp, Microbiol & Virol Unit, Florence, Italy
[5] Florence Careggi Univ Hosp, Hosp Pharm & Drug Policies Unit, Florence, Italy
关键词
airborne viral spread; COVID-19; heat and humidity exchange filter; infection prevention and control; invasive ventilation; SARS-CoV-2; viral load; MOISTURE EXCHANGERS;
D O I
10.1016/j.bja.2022.08.031
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:E163 / E164
页数:2
相关论文
共 8 条
  • [1] Personal protective equipment provision amongst Chinese anaesthesia departments before and after the outbreak of COVID-19
    Du, Ying-Jie
    Song, Jian-Qiang
    Wu, Li-Li
    Cheng, Hao
    Li, Jun
    Wang, Lei
    Wang, Gu-Yan
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2022, 128 (05) : E317 - E320
  • [2] Rapid screening for SARS-CoV-2 VOC-Alpha (202012/01, B.1.1.7) using the Allplex™ SARS-CoV-2/FluA/FluB/RSV Assay
    Giovacchini, Nicla
    Coppi, Marco
    Aiezza, Noemi
    Baccani, Ilaria
    Malentacchi, Francesca
    Pollini, Simona
    Antonelli, Alberto
    Rossolini, Gian Maria
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2021, 113 : 207 - 209
  • [3] Guidelines on the management of acute respiratory distress syndrome
    Griffiths, Mark J. D.
    McAuley, Danny Francis
    Perkins, Gavin D.
    Barrett, Nicholas
    Blackwood, Bronagh
    Boyle, Andrew
    Chee, Nigel
    Connolly, Bronwen
    Dark, Paul
    Finney, Simon
    Salam, Aemun
    Silversides, Jonathan
    Tarmey, Nick
    Wise, Matt P.
    Baudouin, Simon V.
    [J]. BMJ OPEN RESPIRATORY RESEARCH, 2019, 6 (01)
  • [4] HEAT AND MOISTURE EXCHANGERS AND BREATHING FILTERS
    HEDLEY, RM
    ALLTGRAHAM, J
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (02) : 227 - 236
  • [5] Can breathing circuit filters help prevent the spread of influenza A (H1N1) virus from intubated patients?
    Heuer, Jan F.
    Crozier, Thomas A.
    Howard, Glenn
    Quintel, Michael
    [J]. GMS HYGIENE AND INFECTION CONTROL, 2013, 8 (01):
  • [6] A straightforward molecular strategy to retrospectively investigate the spread of SARS-CoV-2 VOC202012/01 B.1.1.7 variant
    Ibba, Gabriele
    Sau, Rosangela
    Angioj, Flavia
    Abbondio, Marcello
    Rubino, Salvatore
    Uzzau, Sergio
    [J]. JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2021, 15 (02): : 242 - +
  • [7] Noninvasive sampling of the distal airspace via HME-filter fluid is not useful to detect SARS-CoV-2 in intubated patients
    Reifart, Joerg
    Liebetrau, Christoph
    Troidl, Christian
    Madlener, Katharina
    Rolf, Andreas
    [J]. CRITICAL CARE, 2021, 25 (01)
  • [8] Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2-practical use, including problems, and their use with paediatric patients
    Wilkes, A. R.
    [J]. ANAESTHESIA, 2011, 66 (01) : 40 - 51