Transcritical CO2 refrigerator and sub-critical R134a refrigerator: A comparison of the experimental results

被引:18
作者
Aprea, Ciro [1 ]
Maiorino, Angelo [1 ]
机构
[1] Univ Salerno, Dept Mech Engn, I-84084 Salerno, Italy
关键词
carbon dioxide; R134a; energy performances comparison; experimental plant; CARBON-DIOXIDE; PERFORMANCE; PRESSURE; SYSTEM; CYCLE;
D O I
10.1002/er.1529
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper describes experiments comparing a commercial available R134a refrigeration plant subjected to a cold store and a prototype R744 (carbon dioxide) system working as a classical 'split-systems' to cool air in residential applications in a transcritical cycle. Both plants are able to develope a refrigeration power equal to 3000 W. The R744 system utilizes aluminium heat exchangers, a semi-hermetic compressor, a back-pressure valve and a thermostatic expansion valve. The R134a refrigeration plant operates using a semi-hermetic reciprocating compressor, an air condenser followed by a liquid receiver, a manifold with two expansion valves, a thermostatic one and a manual one mounted in parallel, and an air cooling evaporator inside the cold store. System performances are compared for two evaporation temperatures varying the temperature of the external air running over the gas-cooler and over the condenser. The refrigeration load in the cold store is simulated by means of some electrical resistances, whereas the air evaporator of the R744 plant is placed in a very large ambient. The results of the comparison are discussed in terms of temperature of the refrigerants at the compressor discharge line, of refrigerants mass flow rate and of coefficient of performance (COP). The performances measured in terms of COPs show a decrease with respect to the R134a plant working at the same external and internal conditions. Further improvements regarding the components of the cycle are necessary to use in a large-scale 'split-systems' working with the carbon dioxide. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 21 条
  • [1] Optimization of two-stage transcritical carbon dioxide heat pump cycles
    Agrawal, Neeraj
    Bhattacharyya, Souvik
    Sarkar, J.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (02) : 180 - 187
  • [2] Refrigeration plant exergetic analysis varying the compressor capacity
    Aprea, C
    de Rossi, F
    Greco, A
    Renno, C
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (07) : 653 - 669
  • [3] An experimental evaluation of the transcritical CO2 refrigerator performances using an internal heat exchanger
    Aprea, Ciro
    Maiorino, Angelo
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06): : 1006 - 1011
  • [4] BEAVER AC, 1999, CR18 ACRC U ILL
  • [5] Flash gas bypass for improving the performance of transcritical R744 systems that use microchannel evaporators
    Elbel, S
    Hrnjak, P
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07): : 724 - 735
  • [6] Second law analysis of the transcritical CO2 refrigeration cycle
    Fartaj, A
    Ting, DSK
    Yang, WW
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) : 2269 - 2281
  • [7] HANSON OW, 2001, Patent No. 6318118
  • [8] Hesse U., 1993, ALTERNATIVES CFCS HC, P317
  • [9] An experimental study of flow boiling characteristics of carbon dioxide in multiport mini channels
    Huai, XL
    Koyama, S
    Zhao, TS
    Shinmura, E
    Hidehiko, K
    Masaki, M
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (10) : 1443 - 1463
  • [10] Determination of the optimum high pressure for transcritical CO2-refrigeration cycles
    Kauf, F
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 1999, 38 (04) : 325 - 330