Initial Experience of Pacing with a Lumenless Lead System in Patients with Congenital Heart Disease

被引:9
|
作者
Chakrabarti, Santabhanu [1 ,2 ]
Morgan, Gareth J. [1 ,2 ]
Kenny, Damien [1 ,2 ]
Walsh, Kevin P. [3 ]
Oslizlok, Paul [3 ]
Martin, Robin P. [1 ,2 ]
Turner, Mark S. [1 ,2 ]
Stuart, A. Graham [1 ,2 ]
机构
[1] Bristol Royal Hosp Children, Bristol Congenital Cardiac Ctr, Bristol BS2 8BJ, Avon, England
[2] Bristol Royal Infirm & Gen Hosp, Bristol BS2 8BJ, Avon, England
[3] Our Ladys Hosp Sick Children, Dublin, Ireland
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 11期
关键词
Pediatrics; Pacing; CHILDREN; MULTICENTER; OPERATION; DELIVERY; BIPOLAR;
D O I
10.1111/j.1540-8159.2009.02487.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Long-term pacing is frequently necessary in patients with congenital heart disease (CHD). Preservation of ventricular function and avoidance of venous occlusion is important in these patients. Site-selective pacing with a smaller diameter lead is achievable with the model 3830 lead (SelectSecure (R), Medtronic Inc., Minneapolis, MN, USA), which was specifically designed to target these complications. We describe our initial experience with the Model 3830 lead in patients with CHD. Methods: Retrospective analysis of all patients undergoing site-selective implantation of a Model 3830 lead(s) from two congenital heart centers (Bristol, UK, and Dublin, Ireland) from October 2004 until February 2008. Results: We implanted 139 SelectSecure (R) leads (atrial n = 70; ventricular n = 69) in 90 patients (57 male) with CHD. Median age at implantation: 13.4 years (1.1-59.2 years), median weight: 43 kg. Sixty-nine patients (76%) were children (< 18 years). Indications for lead implantation included atrioventricular block (n = 55), sinus node disease (n = 18), implantable cardiac defibrillator (n = 12), antitachycardia pacing (n = 4), and cardiac resynchronization (n = 1). Twenty-two patients underwent pre-existing lead extraction during the same procedure. All the attempted procedures resulted in successful pacing. One patient had a significantly raised threshold at implantation. There was no procedural mortality. There were two procedural complications. Three patients required lead repositioning for increasing thresholds early postprocedure (< 6 weeks). Four leads (2.9%) had displaced on median follow-up of 21.8 months (0.5-42 months). Conclusions: The Model 3830 lead is safe and effective in patients with CHD. This is a technically challenging patient group yet procedural complication and lead displacement rates are acceptable. (PACE 2009; 32: 1428-1433)
引用
收藏
页码:1428 / 1433
页数:6
相关论文
共 50 条
  • [1] Lumenless Pacing Leads: Performance and Extraction in Pediatrics and Congenital Heart Disease
    Garnreiter, Jason
    Whitaker, Patricia
    Pilcher, Thomas
    Etheridge, Susan
    Saarel, Elizabeth
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (01): : 42 - 47
  • [2] Performance of the Lumenless 4.1-Fr Diameter Pacing Lead Implanted at Alternative Pacing Sites in Congenital Heart: A Chronic 5-Year Comparison
    Khan, Asra
    Zelin, Kathleen
    Karpawich, Peter P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (12): : 1467 - 1474
  • [3] Transatrial Lead Implantation Using the 4-Fr Lumenless Pacing Lead and Delivery System in Young Adults with Congenital Heart Disease
    Fishberger, Steven B.
    Rollinson, Nancy R.
    Warsy, Irfan
    Wang, Brian
    Kim, Richard W.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12): : e40 - e42
  • [4] Ten-Year Clinical Experience with the Lumenless, Catheter-Delivered, 4.1-Fr Diameter Pacing Lead in Patients with and without Congenital Heart
    Bansal, Neha
    Samuel, Sharmeen
    Zelin, Kathleen
    Karpawich, Peter P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (01): : 17 - 25
  • [5] Bipolar Lumenless Lead Performance in Children and Adults with Congenital Heart Disease
    Daccarett, Marcos
    Segerson, Nathan M.
    Bradley, David J.
    Etheridge, Susan P.
    Freedman, Roger A.
    Saarel, Elizabeth Vickers
    CONGENITAL HEART DISEASE, 2010, 5 (02) : 149 - 156
  • [6] Indications for pacing in patients with congenital heart disease
    Villain, Elisabeth
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 : S17 - S20
  • [7] Comparative Chronic Valve and Venous Effects of Lumenless versus Stylet-Delivered Pacing Leads in Patients with and Without Congenital Heart
    Bharmanee, Apinya
    Zelin, Kathleen
    Sanil, Yamuna
    Gupta, Pooja
    Karpawich, Peter P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (11): : 1343 - 1350
  • [8] Pacing in Patients with Congenital Heart Disease: When Is It Helpful and When Is It Harmful?
    Weiland, M. David
    Spector, Zebulon
    Idriss, Salim F.
    CURRENT CARDIOLOGY REPORTS, 2020, 22 (01)
  • [9] Extraction of Chronic Pacing Lead and Angioplasty for Complete Superior Baffle Obstruction in Complex Congenital Heart Disease
    Sadagopan, Shankar N.
    Veldtman, Gruschen R.
    Roberts, Paul R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (12): : 1661 - 1663
  • [10] Conduction System Pacing in Pediatrics and Congenital Heart Disease, a Single Center Series of 24 Patients
    Gordon, Amanda
    Jimenez, Erick
    Cortez, Daniel
    PEDIATRIC CARDIOLOGY, 2024, 45 (06) : 1165 - 1171