Initial Experience of Pacing with a Lumenless Lead System in Patients with Congenital Heart Disease

被引:9
作者
Chakrabarti, Santabhanu [1 ,2 ]
Morgan, Gareth J. [1 ,2 ]
Kenny, Damien [1 ,2 ]
Walsh, Kevin P. [3 ]
Oslizlok, Paul [3 ]
Martin, Robin P. [1 ,2 ]
Turner, Mark S. [1 ,2 ]
Stuart, A. Graham [1 ,2 ]
机构
[1] Bristol Royal Hosp Children, Bristol Congenital Cardiac Ctr, Bristol BS2 8BJ, Avon, England
[2] Bristol Royal Infirm & Gen Hosp, Bristol BS2 8BJ, Avon, England
[3] Our Ladys Hosp Sick Children, Dublin, Ireland
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 11期
关键词
Pediatrics; Pacing; CHILDREN; MULTICENTER; OPERATION; DELIVERY; BIPOLAR;
D O I
10.1111/j.1540-8159.2009.02487.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Long-term pacing is frequently necessary in patients with congenital heart disease (CHD). Preservation of ventricular function and avoidance of venous occlusion is important in these patients. Site-selective pacing with a smaller diameter lead is achievable with the model 3830 lead (SelectSecure (R), Medtronic Inc., Minneapolis, MN, USA), which was specifically designed to target these complications. We describe our initial experience with the Model 3830 lead in patients with CHD. Methods: Retrospective analysis of all patients undergoing site-selective implantation of a Model 3830 lead(s) from two congenital heart centers (Bristol, UK, and Dublin, Ireland) from October 2004 until February 2008. Results: We implanted 139 SelectSecure (R) leads (atrial n = 70; ventricular n = 69) in 90 patients (57 male) with CHD. Median age at implantation: 13.4 years (1.1-59.2 years), median weight: 43 kg. Sixty-nine patients (76%) were children (< 18 years). Indications for lead implantation included atrioventricular block (n = 55), sinus node disease (n = 18), implantable cardiac defibrillator (n = 12), antitachycardia pacing (n = 4), and cardiac resynchronization (n = 1). Twenty-two patients underwent pre-existing lead extraction during the same procedure. All the attempted procedures resulted in successful pacing. One patient had a significantly raised threshold at implantation. There was no procedural mortality. There were two procedural complications. Three patients required lead repositioning for increasing thresholds early postprocedure (< 6 weeks). Four leads (2.9%) had displaced on median follow-up of 21.8 months (0.5-42 months). Conclusions: The Model 3830 lead is safe and effective in patients with CHD. This is a technically challenging patient group yet procedural complication and lead displacement rates are acceptable. (PACE 2009; 32: 1428-1433)
引用
收藏
页码:1428 / 1433
页数:6
相关论文
共 17 条
[1]   Validation of criteria for Selective His Bundle and para-Hisian permanent pacing [J].
Cantu, F. ;
De Filippo, P. ;
Cardano, P. ;
De Luca, A. ;
Gavazzi, A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (12) :1326-1333
[2]  
de Cock CC, 1998, PACE, V21, P536, DOI 10.1111/j.1540-8159.1998.tb00095.x
[3]   Resynchronization therapy in pediatric and congenital heart disease patients - An international multicenter study [J].
Dubin, AM ;
Janousek, J ;
Rhee, E ;
Strieper, MJ ;
Cecchin, F ;
Law, IH ;
Shannon, KM ;
Temple, J ;
Rosenthal, E ;
Zimmerman, FJ ;
Davis, A ;
Karpawich, PP ;
Al Ahmad, A ;
Vetter, VL ;
Kertesz, NJ ;
Shah, M ;
Snyder, C ;
Stephenson, E ;
Emmel, M ;
Sanatani, S ;
Kanter, R ;
Batra, A ;
Collins, KK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) :2277-2283
[4]   Risk factors for venous obstruction in children with transvenous pacing leads [J].
Figa, FH ;
McCrindle, BW ;
Bigras, JL ;
Hamilton, RM ;
Gow, RM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08) :1902-1909
[5]   Factors that influence the development of atrial flutter after the Fontan operation [J].
Fishberger, SB ;
Wernovsky, G ;
Gentles, TL ;
Gauvreau, K ;
Burnett, J ;
Mayer, JE ;
Walsh, EP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (01) :80-86
[6]   CARDIAC-RHYTHM AFTER THE MUSTARD OPERATION FOR COMPLETE TRANSPOSITION OF THE GREAT-ARTERIES [J].
FLINN, CJ ;
WOLFF, GS ;
DICK, M ;
CAMPBELL, RM ;
BORKAT, G ;
CASTA, A ;
HORDOF, A ;
HOUGEN, TJ ;
KAVEY, RE ;
KUGLER, J ;
LIEBMAN, J ;
GREENHOUSE, J ;
HEES, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (25) :1635-1638
[7]   Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance [J].
Gammage, Michael D. ;
Lieberman, Randy A. ;
Yee, Raymond ;
Manolis, Antonis S. ;
Compton, Steven J. ;
Khazen, Cesar ;
Schaaf, Katie ;
Oleson, Kimberly A. ;
Crossley, George H. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (08) :858-865
[8]  
Janousek J, 2006, HEART RHYTHM, V3, pS93
[9]   Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children [J].
Kenny, Damien ;
Walsh, Kevin P. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (07) :834-838
[10]   Alternative delivery of a 4Fr lumenless pacing lead in children [J].
Lapage, Martin J. ;
Rhee, Edward K. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (05) :543-547