摘要
This study investigates solutions for facade renovation of general office buildings built between 1960 and 1980 in the Copenhagen Municipality. 44 buildings are used for the study. They share common structural and construction principles like the use of beams and columns and prefabricated elements. The problems that face these buildings are a high number of overheating hours and high heating consumption. Four strategies are tested for the renovation: external re-insulation, double-skin facade (existing inner facade), double-skin facade (new inner facade) and curtain wall. External re-insulation and curtain wall provide the best results for reducing the energy consumption for heating. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:937 / 942
页数:6
相关论文
共 11 条
[1]  
[Anonymous], 2007, 156 CCENTC
[2]  
[Anonymous], 2014, VELUX DAYL VIS 2
[3]  
[Anonymous], 2015, EN WIND
[4]  
Danish standard, 2011, DS 418 CALC HEAT LOS
[5]  
Danish Working Environment Authority, 2014, ARB
[6]  
Energy Agency, 2011, BACKG REP BUILD CLAS
[7]  
Energy Agency, 2014, EN
[8]  
Gram J. E., 2015, COMMUNICATION APR
[9]  
IDA indoor climate and energy, 2014, IDA ICE VERS 4 6 1
[10]  
Kalkerup J., 2014, FACADE SYSTEMS EXIST