A contactless conductivity detector for capillary electrophoresis:: Effects of the detection cell geometry on the detector performance

被引:0
|
作者
Tuma, P [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, CZ-12843 Prague 2, Czech Republic
关键词
capillary electrophoresis; conductometric detection; contactless detection; detection cell geometry;
D O I
10.1002/1522-2683(200211)23:21<3718::AID-ELPS3718>3.0.CO;2-U
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.
引用
收藏
页码:3718 / 3724
页数:7
相关论文
共 50 条
  • [31] Indium tin oxide coated PET film contactless conductivity detector for microchip capillary electrophoresis
    Yan, Xingxing
    Liu, Wenfang
    Yuan, Yu
    Chen, Chuanpin
    ANALYTICAL METHODS, 2015, 7 (12) : 5295 - 5302
  • [32] Simultaneous separation of inorganic anions and cations using capillary electrophoresis with a movable contactless conductivity detector
    Unterholzner, V
    Macka, M
    Haddad, PR
    Zemann, A
    ANALYST, 2002, 127 (06) : 715 - 718
  • [33] Dual photometric-contactless conductometric detector for capillary electrophoresis
    Chvojka, T
    Jelínek, I
    Opekar, F
    Stulík, K
    ANALYTICA CHIMICA ACTA, 2001, 433 (01) : 13 - 21
  • [34] Integration of a contactless conductivity detector into a commercial capillary cassette -: Detection of inorganic cations and catecholamines
    Vuorinen, PS
    Jussila, M
    Sirén, H
    Palonen, S
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) : 45 - 52
  • [35] HIGH-FREQUENCY CONTACTLESS CONDUCTIVITY DETECTOR FOR CAPILLARY ISOTACHOPHORESIS
    GAS, B
    VACIK, J
    CHEMICKE LISTY, 1980, 74 (06): : 652 - 658
  • [36] Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry
    Kuban, P
    Hauser, PC
    ELECTROPHORESIS, 2004, 25 (20) : 3387 - 3397
  • [37] Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis
    Tan Feng
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (02) : 152 - 157
  • [38] Separation of enantiomers in capillary electrophoresis with contactless conductivity detection
    Gong, XY
    Kubán, P
    Tanyanyiwa, J
    Hauser, PC
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (02) : 230 - 234
  • [39] Dual confocal laser-induced fluorescence/moveable contactless conductivity detector for capillary electrophoresis microchip
    Shen, Feng
    Yu, Yong
    Yang, Meng
    Kang, Qi
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2009, 15 (06): : 881 - 885
  • [40] A simplified poly(dimethylsiloxane) capillary electrophoresis microchip integrated with a low-noise contactless conductivity detector
    Liu, Benyan
    Zhang, Yi
    Mayer, Dirk
    Krause, Hans-Joachim
    Jin, Qinghui
    Zhao, Jianlong
    Offenhaeusser, Andreas
    ELECTROPHORESIS, 2011, 32 (6-7) : 699 - 704