A contactless conductivity detector for capillary electrophoresis:: Effects of the detection cell geometry on the detector performance

被引:0
|
作者
Tuma, P [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, CZ-12843 Prague 2, Czech Republic
关键词
capillary electrophoresis; conductometric detection; contactless detection; detection cell geometry;
D O I
10.1002/1522-2683(200211)23:21<3718::AID-ELPS3718>3.0.CO;2-U
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.
引用
收藏
页码:3718 / 3724
页数:7
相关论文
共 50 条
  • [21] Dual detector with fluorescence/contactless conductometry for capillary electrophoresis
    Yang, BC
    Tan, F
    Guan, YF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (05) : 740 - 742
  • [22] Characterisation of Crevice and Pit Solution Chemistries Using Capillary Electrophoresis with Contactless Conductivity Detector
    Nie, Mengyan
    Wharton, Julian A.
    Cranny, Andy
    Harris, Nick R.
    Wood, Robert J. K.
    Stokes, Keith R.
    MATERIALS, 2013, 6 (10): : 4345 - 4360
  • [23] Miniaturized movable contactless conductivity detection cell for capillary electrophoresis
    Macka, M
    Hutchinson, J
    Zemann, A
    Zhang, SS
    Haddad, PR
    ELECTROPHORESIS, 2003, 24 (12-13) : 2144 - 2149
  • [24] Capillary electrophoresis and electrochemical detection with a conventional detector cell
    Durgbanshi, A
    Kok, WT
    JOURNAL OF CHROMATOGRAPHY A, 1998, 798 (1-2) : 289 - 296
  • [25] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [26] Contactless conductivity detection in capillary electrophoresis:: A review
    Kubán, P
    Hauser, PC
    ELECTROANALYSIS, 2004, 16 (24) : 2009 - 2021
  • [27] High frequency conductivity detector for capillary electrophoresis
    Chen, ZG
    Mo, JY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (05): : 801 - 804
  • [28] High Frequency Conductivity Detector for Capillary Electrophoresis
    Chen, Zuan-Guang
    Mo, Jin-Yuan
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2002, 23 (05):
  • [29] Considerations on contactless conductivity detection in capillary electrophoresis
    Baltussen, E
    Guijt, RM
    van der Steen, G
    Laugere, F
    Baltussen, S
    van Dedem, GWK
    ELECTROPHORESIS, 2002, 23 (17) : 2888 - 2893
  • [30] The effects of the electrode system geometry on the properties of contactless conductivity detectors for capillary electrophoresis
    Novotny, M
    Opekar, FE
    Stulik, K
    ELECTROANALYSIS, 2005, 17 (13) : 1181 - 1186