A contactless conductivity detector for capillary electrophoresis:: Effects of the detection cell geometry on the detector performance

被引:0
作者
Tuma, P [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, CZ-12843 Prague 2, Czech Republic
关键词
capillary electrophoresis; conductometric detection; contactless detection; detection cell geometry;
D O I
10.1002/1522-2683(200211)23:21<3718::AID-ELPS3718>3.0.CO;2-U
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.
引用
收藏
页码:3718 / 3724
页数:7
相关论文
共 10 条
  • [1] Dual photometric-contactless conductometric detector for capillary electrophoresis
    Chvojka, T
    Jelínek, I
    Opekar, F
    Stulík, K
    [J]. ANALYTICA CHIMICA ACTA, 2001, 433 (01) : 13 - 21
  • [2] da Silva JAF, 2002, J CHROMATOGR A, V942, P249
  • [3] da Silva JAF, 1998, ANAL CHEM, V70, P4339
  • [4] Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries
    Mayrhofer, K
    Zemann, AJ
    Schnell, E
    Bonn, GK
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (17) : 3828 - 3833
  • [5] Pungor E., 1965, OSCILLOMETRY CONDUCT
  • [6] Improved capacitively coupled conductivity detector for capillary electrophoresis
    Tanyanyiwa, J
    Galliker, B
    Schwarz, MA
    Hauser, PC
    [J]. ANALYST, 2002, 127 (02) : 214 - 218
  • [7] Tuma P, 2001, ELECTROANAL, V13, P989, DOI 10.1002/1521-4109(200108)13:12<989::AID-ELAN989>3.0.CO
  • [8] 2-C
  • [9] Conductivity detection in capillary electrophoresis
    Zemann, AJ
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) : 346 - 354
  • [10] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567