A review on integration and design of desiccant air-conditioning systems for overall performance improvements

被引:40
作者
Gao, D. C. [1 ]
Sun, Y. J. [2 ,3 ]
Ma, Z. [4 ]
Ren, H. [3 ]
机构
[1] Sun Yat Sen Univ, Sch Intelligent Syst Engn, Guangzhou, Peoples R China
[2] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Hong Kong, Peoples R China
[3] City Univ Hong Kong, Shenzhen Res Inst, Shenzhen, Peoples R China
[4] Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW, Australia
关键词
Desiccant air-conditioning; Liquid desiccant; Solid desiccant; System integration; Optimal design; EVAPORATIVE COOLING SYSTEM; THERMAL-ENERGY STORAGE; PHASE-CHANGE MATERIALS; TRI-GENERATION SYSTEM; ORGANIC RANKINE-CYCLE; HEAT-PUMP DRIVEN; OF-THE-ART; LIQUID DESICCANT; DEHUMIDIFICATION SYSTEM; TRIGENERATION SYSTEM;
D O I
10.1016/j.rser.2021.110809
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With independent temperature and humidity control, desiccant air-conditioning (DAC) systems have multi aspect advantages (e.g., high-efficiency moisture control, no ozone-depleting coolants use and easy renewable integration etc.) compared with conventional vapor-compression cooling systems, thereby attracting increasingly more research attention. Recently, many studies have been conducted to improve DAC system overall performance by integrating various energy sub-systems/technologies, improving system configurations and optimizing system designs and controls. This study, therefore, provides a timely and systematic review on the above mentioned studies. The study first overviews three typical DAC system configurations, their operating processes, and the commonly used performance indicators. Second, the study summarizes the main integration approaches of DAC systems. Detailed comparative analysis has been provided regarding these integration approaches. Third, the study presents the DAC system configuration improvements in four main categories, and comparatively analyzes their performance enhancements. Last, the study briefly reviews the DAC system design and control optimizations. Meanwhile, based on the DAC system latest developments, the study provides discussions on pressing issues and recommendations for future works. The study can help improve the understanding of the latest developments on DAC system integration and design for overall performance improvements. Associated discussions and recommendations may help focus the needed efforts on solving the pressing issues and outstanding problems, thereby leading to DAC system further performance improvements.
引用
收藏
页数:25
相关论文
共 133 条
[1]   State-of-the-art in liquid desiccant air conditioning equipment and systems [J].
Abdel-Salam, Ahmed H. ;
Simonson, Carey J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 58 :1152-1183
[2]   Capacity matching in heat-pump membrane liquid desiccant air conditioning systems [J].
Abdel-Salam, Ahmed H. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 48 :166-177
[3]   Thermo-economic performance of a solar membrane liquid desiccant air conditioning system [J].
Abdel-Salam, Ahmed H. ;
Ge, Gaoming ;
Simonson, Carey J. .
SOLAR ENERGY, 2014, 102 :56-73
[4]   Performance improvement of desiccant air conditioner coupled with humidification-dehumidification desalination unit using solar reheating of regeneration air [J].
Abdelgaied, Mohamed ;
Kabeel, A. E. ;
Zakaria, Yehya .
ENERGY CONVERSION AND MANAGEMENT, 2019, 198
[5]   Thermodynamic analysis of an innovative liquid desiccant air conditioning system to supply potable water [J].
Ahmed, M. A. ;
Gandhidasan, P. ;
Zubair, Syed M. ;
Bahaidarah, Haitham M. .
ENERGY CONVERSION AND MANAGEMENT, 2017, 148 :161-173
[6]   Assessment of a novel heat-driven cycle to produce. shaft power and refrigeration [J].
Alelyani, Sami M. ;
Sherbeck, Jonathan A. ;
Fette, Nicholas W. ;
Wang, Yuqian ;
Phelan, Patrick E. .
APPLIED ENERGY, 2018, 215 :751-764
[7]   Performance investigation of solid desiccant evaporative cooling system configurations in different climatic zones [J].
Ali, Muzaffar ;
Vukovic, Vladimir ;
Sheikh, Nadeem Ahmed ;
Ali, Hafiz M. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 97 :323-339
[8]   An illustrated review on solar absorption cooling experimental studies [J].
Aliane, A. ;
Abboudi, S. ;
Seladji, C. ;
Guendouz, B. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 65 :443-458
[9]   Dynamic performance assessment of a solar-assisted desiccant-based air handling unit in two Italian cities [J].
Angrisani, G. ;
Roselli, C. ;
Sasso, M. ;
Tariello, F. .
ENERGY CONVERSION AND MANAGEMENT, 2016, 113 :331-345
[10]   Design of a novel geothermal heating and cooling system: Energy and economic analysis [J].
Angrisani, G. ;
Diglio, G. ;
Sasso, M. ;
Calise, F. ;
d'Accadia, M. Dentice .
ENERGY CONVERSION AND MANAGEMENT, 2016, 108 :144-159