Pt-Ni(OH)2 nanosheets amplified two-way lateral flow immunoassays with smartphone readout for quantification of pesticides

被引:88
作者
Cheng, Nan [1 ]
Shi, Qiurong [1 ]
Zhu, Chengzhou [1 ]
Li, Suiqiong [1 ]
Lin, Yuehe [1 ]
Du, Dan [1 ]
机构
[1] Washington State Univ, Sch Mech & Mat Engn, Pullman, WA 99164 USA
基金
美国食品与农业研究所;
关键词
Smartphone; Lateral flow strip; Pt-Ni(OH)(2) nanosheets; Pesticides; Immunoassay; COMPETITIVE IMMUNOCHROMATOGRAPHIC ASSAY; STRIP; BIOSENSORS; PLATFORM; LIQUID; TIME;
D O I
10.1016/j.bios.2019.111498
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Excessive use of herbicide and insecticide causes bioaccumulation in the environment and increases potential toxicity for people and animals. Portable systems for rapid assays of herbicide and insecticide residues have attracted prominent interests. Here, we developed a two-dimensional (2D) Pt-Ni(OH)(2) nanosheets (NSs) amplified two-way lateral flow immunoassay (LFI) with a smartphone-based readout for simultaneous detection of acetochlor and fenpropathrin. The 2D Pt-Ni(OH)(2) NSs were synthesized and used as the enhanced signal label in the immunoassay due to their high peroxidase-like activity and low migration speed. The two-way LFI was designed to eliminate potential cross-reaction between two targets. Portable detection system was developed based on a smartphone-based readout, which scans the LFI and provides the accurate testing result. The universal use of smartphones makes the developed platform suitable for cheap and on-site applications. Using the integrated platform, detection of acetochlor and fenpropathrin simultaneously was successfully achieved with the detection limits of 0.63 ng/mL and 0.24 ng/mL, respectively. To confirm the performance of the on-site application, we detected 10 non-spiked samples and 3 spiked samples. The obtained detection results were consistent with the data from gas chromatography analysis. The estimated recoveries ranged from 97.12% to 111.46%, indicating the practical reliability of our developed assay. The developed smartphone-based platform exhibits enhanced sensitivity, which provides a promising technique for on-site, multiplex, highly sensitive detection of pesticides.
引用
收藏
页数:7
相关论文
共 34 条
[21]   Novel chemiluminescent immunochromatographic assay using a dual-readout signal probe for multiplexed detection of pesticide residues [J].
Ouyang, Hui ;
Wang, Wenwen ;
Shu, Qi ;
Fu, Zhifeng .
ANALYST, 2018, 143 (12) :2883-2888
[22]   Enzyme-linked immuno-strip biosensor to detect Escherichia coli O157:H7 [J].
Park, Sojung ;
Kim, Hajin ;
Paek, Se-Hwan ;
Hong, Jong Wook ;
Kim, Young-Kee .
ULTRAMICROSCOPY, 2008, 108 (10) :1348-1351
[23]   Smartphone-based biosensors: A critical review and perspectives [J].
Roda, Aldo ;
Michelini, Elisa ;
Zangheri, Martina ;
Di Fusco, Massimo ;
Calabria, Donato ;
Simoni, Patrizia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :317-325
[24]   Gold nanoparticle-based lateral flow assay for detection of staphylococcal enterotoxin B [J].
Rong-Hwa, Shyu ;
Shiao-Shek, Tang ;
Der-Jiang, Chiao ;
Yao-Wen, Hung .
FOOD CHEMISTRY, 2010, 118 (02) :462-466
[25]   Designs, formats and applications of lateral flow assay: A literature review [J].
Sajid, Muhammad ;
Kawde, Abdel-Nasser ;
Daud, Muhammad .
JOURNAL OF SAUDI CHEMICAL SOCIETY, 2015, 19 (06) :689-705
[26]   Multiplexed immunochromatographic test strip for time-resolved chemiluminescent detection of pesticide residues using a bifunctional antibody [J].
Shu, Qi ;
Wang, Limin ;
Ouyang, Hui ;
Wang, Wenwen ;
Liu, Fengquan ;
Fu, Zhifeng .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :908-914
[27]   Gold Nanoparticle Coated Silica Nanorods for Sensitive Visual Detection of microRNA on a Lateral Flow Strip Biosensor [J].
Takalkar, Sunitha ;
Xu, Hui ;
Chen, Jiao ;
Baryeh, Kwaku ;
Qiu, Wanwei ;
Zhao, Julia X. ;
Liu, Guodong .
ANALYTICAL SCIENCES, 2016, 32 (06) :617-622
[28]   Recent advances in emerging 2D nanomaterials for biosensing and bioimaging applications [J].
Wen, Wei ;
Song, Yang ;
Yan, Xu ;
Zhu, Chengzhou ;
Du, Dan ;
Wang, Shengfu ;
Asiri, Abdullah M. ;
Lin, Yuehe .
MATERIALS TODAY, 2018, 21 (02) :164-177
[29]   Pt/Ni(OH)2-NiOOH/Pd multi-walled hollow nanorod arrays as superior electrocatalysts for formic acid electrooxidation [J].
Xu, Han ;
Ding, Liang-Xin ;
Feng, Jin-Xian ;
Li, Gao-Ren .
CHEMICAL SCIENCE, 2015, 6 (12) :6991-6998
[30]   A novel fluorimetric sensing platform for highly sensitive detection of organophosphorus pesticides by using egg white-encapsulated gold nanoclusters [J].
Yan, Xu ;
Li, Hongxia ;
Hu, Tianyu ;
Su, Xingguang .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :232-237