Ruptured or intact: What can linear echoes within silicone breast implants tell us?

被引:6
作者
Palmon, LU
Foshager, MC
Parantainen, H
Everson, LI
Cunningham, B
机构
[1] UNIV MINNESOTA,HOSP & CLIN,DEPT RADIOL,MINNEAPOLIS,MN 55455
[2] UNIV MINNESOTA,HOSP & CLIN,DEPT PLAST SURG,MINNEAPOLIS,MN 55455
关键词
D O I
10.2214/ajr.168.6.9168734
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, During sonographic evaluation of silicone breast implants for possible rupture, we have frequently encountered several patterns of linear echoes within the implants, To our knowledge, the significance of this finding has not been established in the literature. The purpose of this study was to determine whether internal echoes are significant in predicting implant rupture. SUBJECTS AND METHODS. Thirty-three patients with 64 silicone implants were prospectively entered into a study that included gray-scale sonography of the implants and subsequent surgical removal, Echo patterns within the implants were retrospectively evaluated on hard-copy films and compared with the integrity of the implant at surgery. RESULTS, Three categories of internal echo patterns were identified: ''thick linear echoes,'' ''thin linear echoes,'' and ''commas.'' One or more of these echo patterns were seen in 57 (89%) of the 64 implants, Thick linear echoes were seen in 23 (36%) of the 64 implants, thin linear echoes were seen in 33 (52%) of the 61 implants, and commas were seen in 47 (73%) of the 64 implants, All echo patterns were seen in intact and ruptured implants with nearly equal frequency. We found no statistical significance for any echo pattern in predicting whether an implant was ruptured or intact. Of the 64 implants, four were entirely free of internal echoes. All four implants were intact. CONCLUSION, A variety of linear echoes can be seen in most silicone breast implants on gray-scale sonography. The presence or absence of linear echoes is not useful in predicting implant rupture. Complete absence of internal echoes, while highly predictive of an intact implant, is infrequently seen.
引用
收藏
页码:1595 / 1598
页数:4
相关论文
共 15 条
[1]   THE DIAGNOSIS OF RUPTURED BREAST IMPLANTS [J].
ANDERSEN, B ;
HAWTOF, D ;
ALANI, H ;
KAPETANSKY, D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (06) :903-907
[2]   DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA ;
KUHLMAN, JE .
RADIOGRAPHICS, 1993, 13 (06) :1323-1336
[3]  
BURKHARDT B, 1988, POSTMASTECTOMY RECON, P68
[4]   BREAST IMPLANT RUPTURE - DIAGNOSIS WITH US [J].
CASKEY, CI ;
BERG, WA ;
ANDERSON, ND ;
SHETH, S ;
CHANG, BW ;
HAMPER, UM .
RADIOLOGY, 1994, 190 (03) :819-823
[5]   ULTRASOUND MAMMOGRAPHY FOR THE AUGMENTED BREAST [J].
COLEBEUGLET, C ;
SCHWARTZ, G ;
KURTZ, AB ;
PATCHEFSKY, AS ;
GOLDBERG, BB .
RADIOLOGY, 1983, 146 (03) :737-742
[6]  
Cronin TD., 1964, EXCERPTA MED, V66, P41
[7]   SILICONE BREAST IMPLANTS - US EVALUATION [J].
DEBRUHL, ND ;
GORCZYCA, DP ;
AHN, CY ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1993, 189 (01) :95-98
[8]   AUGMENTATION MAMMAPALSTY - NORMAL AND ABNORMAL FINDINGS WITH MAMMOGRAPHY AND ULTRASOUND [J].
GANOTT, MA ;
HARRIS, KM ;
ILKHANIPOUR, ZS ;
COSTAGRECO, MA .
RADIOGRAPHICS, 1992, 12 (02) :281-295
[9]   SILICONE IMPLANT RUPTURE - DETECTION WITH US [J].
HARRIS, KM ;
GANOTT, MA ;
SHESTAK, KC ;
LOSKEN, HW ;
TOBON, H .
RADIOLOGY, 1993, 187 (03) :761-768
[10]   THE BASIS OF THE FDAS DECISION ON BREAST IMPLANTS [J].
KESSLER, DA .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (25) :1713-1715