Economic assessment of flexibility offered by an optimally controlled hybrid heat pump generator: a case study for residential building

被引:7
作者
D'Ettorre, F. [1 ,2 ]
De Rosa, M. [2 ]
Conti, P. [1 ]
Schito, E. [1 ]
Testi, D. [1 ]
Finn, D. P. [2 ]
机构
[1] Univ Pisa, Dept Energy Syst Terr & Construct Engn DESTEC, BETTER Bldg Energy Tech & Technol Res Grp, I-56122 Largo L Lazzarino, Italy
[2] Univ Coll Dublin, UCD Energy Inst, OBrien Ctr Sci, Dublin 4, Ireland
来源
ATI 2018 - 73RD CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION | 2018年 / 148卷
关键词
Flexibility; Demand Side Management (DSM); Model Predictive Control (MPC); Hybrid Heat Pump; Thermal Energy Storage (TES); ENERGY; OPTIMIZATION; SYSTEMS;
D O I
10.1016/j.egypro.2018.08.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ongoing decarbonisation process of the current energy system, driven by the EU directives, requires that more renewable energy sources are integrated in the global energy mix, as well as policies promoting investments in new low-carbon technologies, energy efficiency and grid infrastructure. The technical integration of renewable energy sources into the existing power system is not straightforward, due to the intrinsic aleatory characteristics of renewable production, which make the power grid balance harder. To handle this issue, beside the traditional supply-side management, grid flexibility can also be provided by enabling the active participation of the demand-side in power system operational procedures, by means of the so-called demand-side management (DSM). The present paper is aimed at assessing the ability of a cost-optimal control strategy, based on model predictive control, to activate demand-response (DR) actions in a residential building equipped with a hybrid heat pump generator coupled with a water thermal storage. Hourly electricity prices are considered as external signals from the grid driving the demand response actions. It is shown that the thermal energy storage turns out to be an effective way to improve the controller performances and make the system more flexible and able to provide services to the power grid. A daily cost-saving up to 35% and 15% have been highlighted with a 1 m(3) and 0.5 m(3) tanks, respectively. Finally, the achievable flexibility is shown to be strictly dependent on the storage capacity and operations, which in turn are affected by the generators sizing. (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1222 / 1229
页数:8
相关论文
共 15 条
[1]   A summary of demand response in electricity markets [J].
Albadi, M. H. ;
El-Saadany, E. F. .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (11) :1989-1996
[2]   Domestic demand-side management (DSM): Role of heat pumps and thermal energy storage (TES) systems [J].
Arteconi, A. ;
Hewitt, N. J. ;
Polonara, F. .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :155-165
[3]   Sizing strategy of on-off and modulating heat pump systems based on annual energy analysis [J].
Bagarella, G. ;
Lazzarin, R. ;
Noro, M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 65 :183-193
[4]   Analysis of energy demand in residential buildings for different climates by means of dynamic simulation [J].
Bianco, Vincenzo ;
De Rosa, Mattia ;
Scarpa, Federico ;
Tagliafico, Luca A. .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2016, 37 (02) :108-120
[5]   Impacts of large-scale Intermittent Renewable Energy Sources on electricity systems, and how these can be modeled [J].
Brouwer, Anne Sjoerd ;
van den Broek, Machteld ;
Seebregts, Ad ;
Faaij, Andre .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 33 :443-466
[6]   Quantification of flexibility in buildings by cost curves - Methodology and application [J].
De Coninck, Roe ;
Helsen, Lieve .
APPLIED ENERGY, 2016, 162 :653-665
[7]  
European Committee for Standardization, 2013, 148252013 EN
[8]  
European Committee for Standardization, 2008, 156032008 EN
[9]  
Italian Committee for Standardization, 2012, 11300 UNITS IT COM 4
[10]  
Kalaiselvam S, 2014, THERMAL ENERGY STORA, V148, P148, DOI [10.1016/C2013-0-09744-7, DOI 10.1016/C2013-0-09744-7]