Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties

被引:37
作者
Martin, Arno [1 ]
von Strempel, A. [1 ]
机构
[1] Med Univ Innsbruck, Acad Teaching Hosp, Dept Orthoped Surg, A-6800 Feldkirch, Austria
关键词
D O I
10.1097/01/blo.0000218738.69247.d8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Optimal component position in all planes and well-balanced soft tissues facilitate a good clinical outcome and long-term survival after total knee arthroplasties. We investigated the accuracy of implantation of navigated total knee arthroplasties at 3 months followup and the influence on the clinical outcome at 2 years followup. Forty-four patients (44 procedures) were enrolled in our prospective study. One half of the surgeries were performed using a computed tomography-based navigation system, and half were performed with imageless navigation. Outcomes were based on the Insall knee score parameters, anterior knee pain, patient satisfaction, feeling of instability, and step test. The radiographic parameters were the mechanical axis, tibial slope, lateral distal femoral angle, and medial proximal tibial angle. The radiographic measurements were similar in both groups (patients within +/- 3 degrees inaccuracy range in computed tomography-based/imageless groups; mechanical axis 86%/81%, tibial slope 95%/91%, lateral distal femoral angle 95%/91%, medial proximal tibia] angle 91%/95%). The imageless system provided equal radiographic results, but we found improved ligament balancing in the computed tomography free group. The computed tomography-based approach has a good preoperative planning procedure, but is more expensive and time consuming.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 36 条
[21]   The accuracy of image-guided knee replacement based on computed tomography [J].
Nabeyama, R ;
Matsuda, S ;
Miura, H ;
Mawatari, T ;
Kawano, T ;
Iwamoto, Y .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :366-371
[22]  
Oberst M, 2003, UNFALLCHIRURG, V106, P941, DOI 10.1007/s00113-003-0686-6
[23]   Navigation in total-knee arthroplasty -: CT-based implantation compared with the conventional technique [J].
Perlick, L ;
Bäthis, H ;
Tingart, M ;
Perlick, C ;
Grifka, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04) :464-470
[24]  
Petersen T L, 1988, J Arthroplasty, V3, P67, DOI 10.1016/S0883-5403(88)80054-8
[25]  
RAND JA, 1988, CLIN ORTHOP RELAT R, P168
[26]  
RITTER MA, 1994, CLIN ORTHOP RELAT R, P153
[27]   The Swedish Knee Arthroplasty Register 1975-1997 - An update with special emphasis on 41,223 knees operated on in 1988-1997 [J].
Robertsson, O ;
Knutson, K ;
Lewold, S ;
Lidgren, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (05) :503-513
[28]  
Saragaglia D, 2001, REV CHIR ORTHOP, V87, P18
[29]  
SHEINKOP MB, 2004, FEEDBACK CLIN OUTCOM
[30]   Positioning of total knee arthroplasty with and without navigation support - A prospective, randomised study [J].
Sparmann, M ;
Wolke, B ;
Czupalla, H ;
Banzer, D ;
Zink, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :830-835