Force-displacement behavior of unbonded post-tensioned concrete walls

被引:26
作者
Hassanli, Reza [1 ]
ElGawady, Mohamed A. [2 ]
Mills, Julie E. [1 ]
机构
[1] Univ S Australia, Adelaide, SA 5001, Australia
[2] Missouri Univ Sci & Technol, Rolla, MO USA
关键词
Post-tensioned; Concrete walls; Seismic response; Force-displacement behavior; LATERAL LOAD BEHAVIOR;
D O I
10.1016/j.engstruct.2015.10.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper the behavior of unbonded post-tensioned concrete walls (PT-CWs) was studied. The accuracy of the existing equations provided in international concrete codes in predicting the in-plane flexural strength of unbonded PT-CWs was investigated using a database of 30 walls. Two recently developed models for unbonded wall members with varying distributions of tendons along the wall length were also considered. An analytical procedure, based on the mechanics of rocking walls and geometric compatibility conditions was employed to characterize the lateral force behavior of unbonded PT-CWs. Using the experimental results, the displacement ductility was determined for the considered walls. According to the results, although the expressions provided by the concrete design codes of the United States (AC! 315-14), New Zealand (NZS 3101) and Australia (AS 3600) to calculate the stresses in tendons of unbonded members were originally developed for beam elements, they resulted in a reasonable strength prediction of wall members. However, the concrete design code of Canada (CSA-A23.3-04) provides a highly unconservative prediction of the flexural strength of unbonded PT-CWs. The presented analytical procedure was able to effectively predict the capacity curve of the tested walls. This research also showed that at low levels of axial stress ratio the ductility of unbonded PT-CWs is highly sensitive to small changes in the level of axial stress. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:495 / 505
页数:11
相关论文
共 28 条
  • [1] A simplified analysis method for characterizing unbonded post-tensioned precast wall systems
    Aaleti, Sriram
    Sritharan, Sri
    [J]. ENGINEERING STRUCTURES, 2009, 31 (12) : 2966 - 2975
  • [2] ACI Innovation Task Group 5.2, 2009, Requirements for Design of a Special Unbonded Post-Tensioned Precast Shear Wall Satisfying ACI ITG-5.1 (ACI ITG- 5.2-9) and Commentary
  • [3] [Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
  • [4] [Anonymous], 2009, AS3600
  • [5] [Anonymous], 2014, 318 ACI
  • [6] [Anonymous], THESIS
  • [7] [Anonymous], 2007, ACC CRIT SPEC UNB PO
  • [8] Building Seismic Safety Council, 2001, Report FEMA 368
  • [9] Behaviour of steel-fibre-reinforced normal-strength concrete slender columns under cyclic loading
    Caballero-Morrison, K. E.
    Bonet, J. L.
    Navarro-Gregori, Juan
    Marti-Vargas, J. R.
    [J]. ENGINEERING STRUCTURES, 2012, 39 : 162 - 175
  • [10] Calvi G.M., 2007, NZSEE C