Optimising sampling rates for accelerometer-based human activity recognition

被引:108
作者
Khan, Aftab [1 ]
Hammerla, Nils [2 ]
Mellor, Sebastian [2 ]
Ploetz, Thomas [2 ]
机构
[1] Toshiba Res Europe Ltd, Telecommun Res Lab, Bristol, Avon, England
[2] Newcastle Univ, Sch Comp Sci, Open Lab, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
Activity recognition; Accelerometers; Sampling rates; Statistics; TUTORIAL;
D O I
10.1016/j.patrec.2016.01.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Real-world deployments of accelerometer-based human activity recognition systems need to be carefully configured regarding the sampling rate used for measuring acceleration. Whilst a low sampling rate saves considerable energy, as well as transmission bandwidth and storage capacity, it is also prone to omitting relevant signal details that are of interest for contemporary analysis tasks. In this paper we present a pragmatic approach to optimising sampling rates of accelerometers that effectively tailors recognition systems to particular scenarios, thereby only relying on unlabelled sample data from the domain. Employing statistical tests we analyse the properties of accelerometer data and determine optimal sampling rates through similarity analysis. We demonstrate the effectiveness of our method in experiments on 5 benchmark datasets where we determine optimal sampling rates that are each substantially below those originally used whilst maintaining the accuracy of reference recognition systems. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 32 条
  • [1] [Anonymous], P ISWC
  • [2] [Anonymous], P DISTR COMP SYST WO
  • [3] [Anonymous], 2010 23 INT C ARCH C
  • [4] [Anonymous], P UBICOMP
  • [5] [Anonymous], P PERCOM
  • [6] [Anonymous], P UBICOMP
  • [7] [Anonymous], P 2012 ACM C UB COMP
  • [8] [Anonymous], P UBICOMP
  • [9] [Anonymous], REAL TIM EMB TECHN A
  • [10] [Anonymous], P ISWC