Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an inorganic particle matrix for small molecule analysis

被引:1
|
作者
Kinumi, T
Saisu, T
Takayama, M
Niwa, H
机构
[1] Univ Electrocommun, Dept Appl Phys & Chem, Chofu, Tokyo 1828585, Japan
[2] Toho Univ, Fac Pharmaceut Sci, Chiba 2748510, Japan
来源
JOURNAL OF MASS SPECTROMETRY | 2000年 / 35卷 / 03期
关键词
matrix-assisted laser desorption/ionization; time-of-flight mass spectrometry; inorganic matrix; rapid heating/vaporization process;
D O I
10.1002/(SICI)1096-9888(200003)35:3<417::AID-JMS952>3.0.CO;2-#
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate. Eleven kinds of particle, Al, Mn, Mo, Si, Sn, SnO2, TiO2, W, WO3, Zn and ZnO, were evaluated. The analyte was mixed with a metal or metal oxide powder (inorganic matrix) with particle diameter of tens of micrometers and liquid dispersant, followed by application to the sample target. Using a commercial MALDI-TOFRMS instrument equipped with an internal 337 nm pulsed nitrogen laser, the analytes, PEG 200 and methyl stearate, were ionized as the alkali metal ion adducted molecules [hl + Na](+) or [M + K](+) when the inorganic matrices Mn, Mo, Si, Sn, TiO2, W, WO3, Zn or ZnO were used. In the case of an Al matrix, PEG 200 was ionized as [hl + K]+, whereas methyl stearate was ionized as [M + H](+) and [M + Al](+). These particles have potential as the matrix for MALDI. During our examination, however, only SnO2 particles did not ionize either PEG 200 or methyl stearate. Based on our protocol, when TiO2 powder was suspended with Liquid paraffin, PEG 200 and methyl stearate gave their MALDI-TOF mass spectra with the lowest background noise and highest intensity. TiO2 powder seemed to be a broad potential matrix for low molecular mass polar or non-polar analytes. The results suggested that bulk particles caused rapid heating/vaporization processes and ionized analyte molecules under irradiation with a pulsed W laser. The present method can be readily applied to obtain the low background noise MALDI-TOF mass spectra of small-sized compounds. Copyright (C) 2000 John Whey gi Sons, Ltd.
引用
收藏
页码:417 / 422
页数:6
相关论文
共 50 条
  • [31] Investigation of the dynamics of matrix-assisted laser desorption ionization ion formation using an electrostatic analyzer/time-of-flight mass spectrometer
    Kinsel, GR
    Gimon-Kinsel, ME
    Gillig, KJ
    Russell, DH
    JOURNAL OF MASS SPECTROMETRY, 1999, 34 (06): : 684 - 690
  • [32] MATRIX-ASSISTED UV AND IR LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF DIAMMINOPLATINUM(II) OLIGODEOXYRIBONUCLEOTIDE ADDUCTS AND THEIR UNPLATINATED ANALOGS
    COSTELLO, CE
    NORDHOFF, E
    HILLENKAMP, F
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03): : 239 - 249
  • [33] Analysis of single nucleotide polymorphism in human paraoxonase 1 gene(Q192R) with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Sun, YD
    Sun, SC
    Wang, Z
    Yang, Y
    Zhang, J
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2006, 22 (03) : 394 - 396
  • [34] Laser-induced dissociation of phosphorylated peptides using matrix assisted laser desorption/ionization tandem time-of-flight mass spectrometry
    Dongxia Wang
    Philip A. Cole
    Robert J. Cotter
    Clinical Proteomics, 2006, 2 (3-4) : 133 - 144
  • [35] Analysis and Quantitation of Glycated Hemoglobin by Matrix Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry
    Hattan, Stephen J.
    Parker, Kenneth C.
    Vestal, Marvin L.
    Yang, Jane Y.
    Herold, David A.
    Duncan, Mark W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (03) : 532 - 541
  • [36] Infrared matrix-assisted laser desorption/ionization quadrupole ion trap mass spectrometry
    Lippa, T
    Taranenko, NI
    Prasad, CR
    Doroshenko, VM
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (03) : 263 - 271
  • [37] Molecular mass determination of plasma-derived glycoproteins by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with internal calibration
    Belgacem, O
    Buchacher, A
    Pock, K
    Josic, D
    Sutton, C
    Rizzi, A
    Allmaier, G
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (11): : 1118 - 1130
  • [38] A new matrix for analyzing low molecular mass compounds and its application for determination of carcinogenic areca alkaloids by matrix-assisted laser desorption ionization time-of-flight mass spectrometry
    Feng, Chia-Hsien
    Lu, Chi-Yu
    ANALYTICA CHIMICA ACTA, 2009, 649 (02) : 230 - 235
  • [39] Application of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Imaging Mass Spectrometry (MALDI-TOF IMS) for Premalignant Gastrointestinal Lesions
    Ko, Kwang Hyun
    Kwon, Chang Il
    Park, So Hye
    Han, Na Young
    Lee, Hoo Keun
    Kim, Eun Hee
    Hahm, Ki Baik
    CLINICAL ENDOSCOPY, 2013, 46 (06) : 611 - 619
  • [40] Sequencing of peptides phosphorylated on serines and threonines by post-source decay in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Hoffmann, R
    Metzger, S
    Spengler, B
    Otvos, L
    JOURNAL OF MASS SPECTROMETRY, 1999, 34 (11): : 1195 - 1204