Investigation of soil thermal saturation and recovery under intermittent and continuous operation of EATHE

被引:52
作者
Mathur, Anuj [1 ]
Surana, Ankit Kumar [2 ]
Verma, Poonam [2 ]
Mathur, Sanjay [2 ]
Agrawal, G. D. [3 ]
Mathur, Jyotirmay [1 ]
机构
[1] Malaviya Natl Inst Technol, Ctr Energy & Environm, Jaipur 302017, Rajasthan, India
[2] Malaviya Natl Inst Technol, Dept Civil Engn, Jaipur 302017, Rajasthan, India
[3] Malaviya Natl Inst Technol, Dept Mech Engn, Jaipur 302017, Rajasthan, India
关键词
EATHE system; Continuous operation; Intermittent operation; Soil thermal saturation; Soil temperature recovery; AIR HEAT-EXCHANGER; INTEGRATED EARTH; PERFORMANCE; SYSTEM;
D O I
10.1016/j.enbuild.2015.10.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the problems in operating earth air tunnel heat exchangers (EATHE) is the collection/rejection of heat from buried pipe to nearby sub-soil which alters the soil temperature, and, in turn, adversely affects the performance of EATHE system with time. This problem is more pronounced with the soil having poor thermal conductivity and little variation in moisture content. Extent thermal saturation and time required for self-recovery of soil around the buried pipe has great importance to ensure efficiency and usefulness of an EATHE system. However, there are hardly any studies on the self-recovery of soil during intermittent operation mode. The objective of present study is to compare the thermal saturation and self-recovery ability of soil in continuous and intermittent operation modes. The numerical results have been validated experimentally through a full scale setup. It is found that the soil temperature can be recovered in both intermittent and continuous operation modes by employing natural heat conduction (heat taken away from the pipe's immediate vicinity) and convection (heat taken away by purge air passing through EATHE in night hours when ambient is lower than soil) respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 303
页数:13
相关论文
共 29 条
[1]   Using Fouggara for Heating and Cooling Buildings in Sahara [J].
Amara, S. ;
Nordell, B. ;
Benyoucef, B. .
IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 :55-64
[2]  
Anderson J.D., 2010, Computational Fluid Dynamics: The Basics with Applications
[3]   Transient effect of soil thermal conductivity and duration of operation on performance of Earth Air Tunnel Heat Exchanger [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agarwal, Ghanshyam ;
Mathur, Jyotirmay .
APPLIED ENERGY, 2013, 103 :1-11
[4]   Performance evaluation and economic analysis of integrated earth-air-tunnel heat exchanger-evaporative cooling system [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2012, 55 :102-108
[5]   Performance analysis of earth-pipe-air heat exchanger for summer cooling [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2010, 42 (05) :645-648
[6]   Performance analysis of earth-pipe-air heat exchanger for winter heating [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2009, 41 (11) :1151-1154
[7]   Passive cooling in a low-energy office building [J].
Breesch, H ;
Bossaer, A ;
Janssens, A .
SOLAR ENERGY, 2005, 79 (06) :682-696
[8]   Theoretical and practical evaluation of an earth-tube (E-tube) ventilation system [J].
Darkwa, J. ;
Kokogiannakis, G. ;
Magadzire, C. L. ;
Yuan, K. .
ENERGY AND BUILDINGS, 2011, 43 (2-3) :728-736
[9]   Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification [J].
Demir, Hakan ;
Koyun, Ahmet ;
Temir, Galip .
APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) :224-233
[10]   Potential of geothermal heat exchangers for office building climatisation [J].
Eicker, Ursula ;
Vorschulze, Christoph .
RENEWABLE ENERGY, 2009, 34 (04) :1126-1133