Utilizing thermal building mass for storage in district heating systems: Combined building level simulations and system level optimization

被引:85
作者
Dominkovic, D. F. [1 ]
Gianniou, P. [2 ]
Munster, M. [3 ]
Heller, A. [4 ]
Rode, C. [2 ]
机构
[1] Tech Univ Denmark DTU, Dept Energy Convers & Storage, Frederiksborgvej 399, Roskilde, Denmark
[2] Tech Univ Denmark DTU, Dept Civil Engn, Niels Koppels Alle, Lyngby, Denmark
[3] Tech Univ Denmark DTU, Dept Management Engn, Prod Torvet, Lyngby, Denmark
[4] Tech Univ Denmark DTU, Dept Civil Engn, Lyngby, Denmark
关键词
Thermal energy storage in buildings; Thermal mass; District heating; Energy supply optimization; Thermal autonomy; Heat flexibility; DEMAND-SIDE MANAGEMENT; ENERGY-STORAGE; RESIDENTIAL BUILDINGS; PUMPS;
D O I
10.1016/j.energy.2018.04.093
中图分类号
O414.1 [热力学];
学科分类号
摘要
Higher shares of intermittent renewable energy in energy systems have raised the issue of the need for different energy storage solutions. The utilization of existing thermal building mass for storage is a cost-efficient solution. In order to investigate its potential, a detailed building simulation model was coupled with a linear optimization model of the energy system. Different building archetypes were modelled in detail, and their potential preheating and subsequent heat supply cut-off periods were assessed. Energy system optimization focused on the impact of thermal mass for storage on the energy supply of district heating. Results showed that longer preheating time increased the possible duration of cut-off events. System optimization showed that the thermal mass for storage was used as intra-day storage. Flexible load accounted for 5.5%-7.7% of the total district heating demand. Furthermore, thermal mass for storage enabled more solar thermal heating energy to be effectively utilized in the system. One of the sensitivity analyses showed that the large-scale pit thermal energy storage and thermal mass for storage are complimentary. The cut-off duration potential, which did not compromise thermal comfort, was longer in the newer, better insulated buildings, reaching 6 h among different building archetypes. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:949 / 966
页数:18
相关论文
共 42 条
[1]  
Aggerholm S, 2013, COST OPTIMAL LEVELS
[2]  
[Anonymous], STRAT EN SOND SOND E
[3]  
[Anonymous], 2002, ASHRAE Research Summary - ASHRAE 1119-TRP, P1
[4]   A new approach to determine the outdoor temperature distributions for building energy calculations [J].
Coskun, Can ;
Erturk, Mustafa ;
Oktay, Zuhal ;
Hepbasli, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2014, 78 :165-172
[5]  
COWL, 2015, SOND KOMM STRAT EN K
[6]   Thermal energy storage for low and medium temperature applications using phase change materials - A review [J].
da Cunha, Jose Pereira ;
Eames, Philip .
APPLIED ENERGY, 2016, 177 :227-238
[7]  
Danish Government, 2014, STRAT EN REN BUILD, P54
[8]  
Dansk Standard, 2007, 15251 DSEN
[9]   The future of transportation in sustainable energy systems: Opportunities and barriers in a clean energy transition [J].
Dominkovic, D. F. ;
Bacekovic, I. ;
Pedersen, A. S. ;
Krajacic, G. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 :1823-1838
[10]   Potential of district cooling in hot and humid climates [J].
Dominkovic, D. F. ;
Rashid, K. A. Bin Abdul ;
Romagnoli, A. ;
Pedersen, A. S. ;
Leong, K. C. ;
Krajacic, G. ;
Duic, N. .
APPLIED ENERGY, 2017, 208 :49-61