Confocal laser scanning microscopy of whole mouse ovaries: Excellent morphology, apoptosis detection, and spectroscopy

被引:14
作者
Zucker, Robert M. [1 ]
Jeffay, Susan C. [1 ]
机构
[1] US EPA, Natl Hlth & Environm Effects Res Lab, Reprod Toxicol Div, Off Res & Dev, Res Triangle Pk, NC 27711 USA
关键词
spectral imaging; spectroscopy PARISS; confocal microscopy; fluorescence; LysoTracker Red; follicle; ovary; oocyte; apoptosis; nucleolus; granulosa cells;
D O I
10.1002/cyto.a.20315
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Ovaries consist of numerous follicles, oocytes, and granulosa cells in different stages of development. Many of these follicles will undergo an apoptotic process during the lifetime of the animal. By using proper tissue preparation methods, the events within the whole ovary can be observed by using 3D confocal microscopy. Methods: Whole ovaries were stained with LysoTracker Red (LT), fixed with 4% paraformaldehyde (PF) and 1% glutaraldehyde (Glut), dehydrated with methanol (MEOH), and cleared with benzyl alcohol and benzyl benzoate (BABB). Using this tissue preparation technique, the ovary becomes relatively transparent, allowing its morphology to be observed with confocal microscopes. A spectral imaging system (PARISS) located on a conventional microscope was used to interpret the LT dye spectra and fixation products in the tissues with different excitation wavelengths. Results: Apoptosis in the follicle was detected as clusters of intensely stained granulosa cells located in close proximity to the oocytes. The fixation with Glut and PF preserved morphological details, increased tissue fluorescence, thus increased the signal to noise of the background image. Conclusions: Thick tissues can be imaged after they are properly stained, aldehyde fixed, and BABB cleared. ET intensely stained single cells or clusters of apoptotic cells in the follicles and the nucleolus. Spectral differences between LT as an indicator of apoptosis and Glut-PF fixation was used to visualize ovarian morphology and apoptosis. The PARISS spectrophotometer revealed spectral peaks for IT at 609.6 nm and for Glut-PF at 471.3 nm. The proper use of the spectra from these fluorescence molecules is the foundation for high quality morphological images of apoptosis. By sequentially imaging the two probes with a 488 run laser and a 543/568 nm laser, there was a reduction in fluorescent cross talk and an increase in image quality. (c) 2006 international Society for Analytical Cytology.
引用
收藏
页码:930 / 939
页数:10
相关论文
共 55 条
  • [1] Control of differentiation, transformation, and apoptosis in granulosa cells by oncogenes, oncoviruses, and tumor suppressor genes
    Amsterdam, A
    Selvaraj, N
    [J]. ENDOCRINE REVIEWS, 1997, 18 (04) : 435 - 461
  • [2] Alternative pathways of ovarian apoptosis: death for life
    Amsterdam, A
    Sasson, R
    Keren-Tal, I
    Aharoni, D
    Dantes, A
    Rimon, E
    Land, A
    Cohen, T
    Dore, Y
    Hirsh, L
    [J]. BIOCHEMICAL PHARMACOLOGY, 2003, 66 (08) : 1355 - 1362
  • [3] Apoptosis in steroidogenic cells: Structure-function analysis
    Amsterdam, A
    Dantes, A
    Selvaraj, N
    Aharoni, D
    [J]. STEROIDS, 1997, 62 (01) : 207 - 211
  • [4] ULTRASTRUCTURAL CYTO-CHEMISTRY OF THE NUCLEOLUS IN RAT OOCYTES AT THE END OF THE FOLLICULOGENESIS
    ANTOINE, N
    LEPOINT, A
    BAECKELAND, E
    GOESSENS, G
    [J]. HISTOCHEMISTRY, 1988, 89 (03) : 221 - 226
  • [5] Fluorescence spectroscopy as a biomarker in a cell culture and in a nonhuman primate model for ovarian cancer chemopreventive agents
    Brewer, M
    Utzinger, U
    Li, Y
    Atkinson, EN
    Satterfield, W
    Auersperg, N
    Richards-Kortum, R
    Follen, M
    Bast, R
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) : 20 - 26
  • [6] Imaging of the ovary
    Brewer, MA
    Utzinger, U
    Barton, JK
    Hoying, JB
    Kirkpatrick, ND
    Brands, WR
    Davis, JR
    Hunt, K
    Stevens, SJ
    Gmitro, AF
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (06) : 617 - 627
  • [7] THE INFLUENCE OF SPECIMEN REFRACTIVE-INDEX, DETECTOR SIGNAL INTEGRATION, AND NONUNIFORM SCAN SPEED ON THE IMAGING PROPERTIES IN CONFOCAL MICROSCOPY
    CARLSSON, K
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1991, 163 : 167 - 178
  • [8] Darzynkiewicz Z, 1997, CYTOMETRY, V27, P1
  • [9] Ultrastructural evaluation of oocytes during atresia in rat ovarian follicles
    Devine, PJ
    Payne, CM
    McCuskey, MK
    Hoyer, PB
    [J]. BIOLOGY OF REPRODUCTION, 2000, 63 (05) : 1245 - 1252
  • [10] Multi-spectral imaging and linear unmixing add a whole new dimension to laser scanning fluorescence microscopy
    Dickinson, ME
    Bearman, G
    Tille, S
    Lansford, R
    Fraser, SE
    [J]. BIOTECHNIQUES, 2001, 31 (06) : 1272 - +