Time-resolved projection MRA: clinical application in intracranial vascular malformations

被引:49
|
作者
Klisch, J
Strecker, R
Henning, J
Schumacher, M
机构
[1] Univ Freiburg, Dept Radiol, Neuroradiol Sect, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Radiol, Sect Med Phys, D-79106 Freiburg, Germany
关键词
magnetic resonance; angiography; time resolved; malformations; vascular; embolisation;
D O I
10.1007/s002340050024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report preliminary results of imaging intracranial vascular malformations with time-resolved projection MRA after a bolus injection of contrast median before and after endovascular treatment. Projection angiograms are acquired with a slice-selective snapshot FLASH sequence with a time resolution of two images per second, 40-60 images being acquired consecutively after bolus injection of 15 ml Gd-DTPA. Postprocessing of images in 2D projection MRA by correlation analysis offers several advantages with significant improvement of signal-to-noise, leading to adequate anatomical resolution. Subsecond projection MRA is a reliable technique for imaging intracranial vessels and gives information about the haemodynamics of vascular malformations.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [41] TIME-RESOLVED FLUOROMETRY - PRINCIPLES AND APPLICATION TO CLINICAL MICROBIOLOGY AND DNA PROBE TECHNOLOGY
    HURSKAINEN, P
    DAHLEN, P
    SIITARI, H
    LOVGREN, T
    RAPID METHODS IN CLINICAL MICROBIOLOGY: PRESENT STATUS AND FUTURE TRENDS, 1989, 263 : 123 - 130
  • [42] Establishment and Clinical Application in Stroke of a Serum Copeptin Time-Resolved Fluorescence Immunoassay
    Zhou, Zixuan
    Sun, Fan
    Jiang, Jingwen
    Dou, Zhijie
    Lv, Yinglei
    Zhang, Zhimin
    Zhou, Xiumei
    Zhao, Xueqin
    Qin, Yuan
    Huang, Biao
    JOURNAL OF FLUORESCENCE, 2024, 34 (05) : 2349 - 2358
  • [43] Dynamic MRA With Four-Dimensional Time-Resolved Angiography Using Keyhole at 3 Tesla in Head and Neck Vascular Lesions
    Parmar, Hemant
    Ivancevic, Marko K.
    Dudek, Nancy
    Gandhi, Dheeraj
    Mukherji, Suresh K.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2009, 29 (02) : 119 - 127
  • [44] Establishment of Time-Resolved Fluorescence Immunoassay for Thyrotropin Receptor Antibodies and Clinical Application
    Shen, Ting
    Yang, Fuzhou
    Wu, Jialong
    Qin, Yuan
    Zhou, Xiumei
    Zhao, Xueqin
    Zhu, Bao
    Huang, Biao
    JOURNAL OF FLUORESCENCE, 2025,
  • [45] Application of time-resolved fluorescence to the determination of metabolites
    Murillo Pulgarin, J. A.
    Alanon Molina, A.
    Martinez Ferreras, F.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 128 : 82 - 90
  • [46] THEORY AND APPLICATION OF TIME-RESOLVED ABSORPTION SPECTROSCOPY
    FUJIMURA, Y
    SCHRODER, H
    LIN, SH
    SCHLAG, EW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 51 - 51
  • [47] APPLICATION OF SYNERGETIC LUMINESCENCE TO TIME-RESOLVED FLUOROIMMUNOASSAY
    李建军
    陈观铨
    曾云鹗
    ChineseScienceBulletin, 1992, (01) : 84 - 85
  • [48] APPLICATION OF LASERS TO TIME-RESOLVED FLOW VISUALIZATION
    TANNER, LH
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (02): : 125 - &
  • [49] APPLICATION OF LASERS TO TIME-RESOLVED FLOW VISUALIZATION
    TANNER, LH
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (06): : 353 - &
  • [50] APPLICATION OF SYNERGETIC LUMINESCENCE TO TIME-RESOLVED FLUOROIMMUNOASSAY
    LI, JJ
    CHEN, GQ
    ZENG, YE
    CHINESE SCIENCE BULLETIN, 1992, 37 (01): : 84 - 85