Time-resolved projection MRA: clinical application in intracranial vascular malformations

被引:49
|
作者
Klisch, J
Strecker, R
Henning, J
Schumacher, M
机构
[1] Univ Freiburg, Dept Radiol, Neuroradiol Sect, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Radiol, Sect Med Phys, D-79106 Freiburg, Germany
关键词
magnetic resonance; angiography; time resolved; malformations; vascular; embolisation;
D O I
10.1007/s002340050024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report preliminary results of imaging intracranial vascular malformations with time-resolved projection MRA after a bolus injection of contrast median before and after endovascular treatment. Projection angiograms are acquired with a slice-selective snapshot FLASH sequence with a time resolution of two images per second, 40-60 images being acquired consecutively after bolus injection of 15 ml Gd-DTPA. Postprocessing of images in 2D projection MRA by correlation analysis offers several advantages with significant improvement of signal-to-noise, leading to adequate anatomical resolution. Subsecond projection MRA is a reliable technique for imaging intracranial vessels and gives information about the haemodynamics of vascular malformations.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [21] The Role of Time-Resolved MRA for Post-treatment Assessment of Pulmonary Arteriovenous Malformations: A Pictorial Essay
    Tatsuya Kawai
    Masashi Shimohira
    Kengo Ohta
    Takuya Hashizume
    Masahiro Muto
    Kazushi Suzuki
    Kenichiro Kurosaka
    Yuta Shibamoto
    CardioVascular and Interventional Radiology, 2016, 39 : 965 - 972
  • [23] Simulation of relative temporal resolution of time-resolved MRA sequences
    Keith, L.
    Kecskemeti, S.
    Velikina, J.
    Mistretta, C.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 398 - 404
  • [24] Clinical Uses of Time-Resolved Imaging in the Body and Peripheral Vascular System
    Cornfeld, Daniel
    Mojibian, Hamid
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : W546 - W557
  • [25] Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels
    Du, J
    Carroll, TJ
    Wagner, HJ
    Vigen, K
    Fain, SB
    Block, WF
    Korosec, FR
    Grist, TM
    Mistretta, CA
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 516 - 522
  • [26] Principles Behind 4D Time-Resolved MRA/Dynamic MRA in Neurovascular Imaging
    Jagadeesan, Bharathi
    Tariq, Farzana
    Nada, Ayman
    Bhatti, Ibrahim A.
    Masood, Kamran
    Siddiq, Farhan
    SEMINARS IN ROENTGENOLOGY, 2024, 59 (02) : 191 - 202
  • [27] Contrast-Enhanced Time-Resolved MRA for Follow-Up of Intracranial Aneurysms Treated with the Pipeline Embolization Device
    Boddu, S. R.
    Tong, F. C.
    Dehkharghani, S.
    Dion, J. E.
    Saindane, A. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) : 2112 - 2118
  • [28] Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms
    Serafin, Zbigniew
    Strzesniewski, Piotr
    Lasek, Wladyslaw
    Beuth, Wojciech
    MEDICAL SCIENCE MONITOR, 2012, 18 (07): : MT60 - MT65
  • [29] TIME-RESOLVED RENAL CONTRAST-ENHANCED MRA IN NORMAL DOGS
    Cavrenne, Romain
    Mai, Wilfried
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (01) : 58 - 64
  • [30] Time-Resolved Lower Extremity MRA With Temporal Interpolation and Stochastic Spiral Trajectories: Preliminary Clinical Experience
    Lim, Ruth P.
    Jacob, Jason S.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Huffman, Steven D.
    Kim, Sooah
    Babb, James S.
    Laub, Gerhard
    Adelman, Mark A.
    Lee, Vivian S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 663 - 672